Whole-Body Voxel-Based Personalized Dosimetry: The Multiple Voxel S-Value Approach for Heterogeneous Media with Nonuniform Activity Distributions
- 14 December 2017
- journal article
- research article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 59 (7) , 1133-1139
Abstract
Personalized dosimetry with high accuracy is becoming more important because of the growing interest in personalized medicine and targeted radionuclide therapy. Voxel-based dosimetry using dose point kernel or voxel S-value (VSV) convolution is available. However, these approaches do not consider the heterogeneity of the medium. Here, we propose a new method for whole-body voxel-based personalized dosimetry in heterogeneous media with nonuniform activity distributions-a method we refer to as the multiple VSV approach. Instead of using only a single VSV, as found in water, the method uses multiple numbers (N) of VSVs to cover media of various density ranges, as found in the whole body. Methods: The VSVs were precalculated using GATE Monte Carlo simulation and were convoluted with the time-integrated activity to generate density-specific dose maps. CT-based segmentation was performed to generate a binary mask image for each density region. The final dose map was acquired by the summation of N segmented density-specific dose maps. We tested several sets of VSVs with different densities: N = 1 (single water VSV), 4, 6, 8, 10, and 20. To validate the proposed method, phantom and patient studies were conducted and compared with the direct Monte Carlo approach, which was considered the ground truth. Finally, dosimetry on 10 patients was performed using the multiple VSV approach and compared with the single VSV and organ-based approaches. Errors at the voxel and organ levels were reported for 8 organs. Results: In the phantom and patient studies, the multiple VSV approach showed significant decreases in voxel-level errors, especially for the lung and bone regions. As the number of VSVs increased, voxel-level errors decreased, although some overestimations were observed at the lung boundaries. For the multiple VSVs (N = 8), we achieved a voxel-level error of 2.06%. In the dosimetry study, our proposed method showed greatly improved results compared with single VSV and organ-based dosimetry. Errors at the organ level were -6.71%, 2.17%, and 227.46% for single VSV, multiple VSV, and organ-based dosimetry, respectively. Conclusion: The multiple VSV approach for heterogeneous media with nonuniform activity distributions offers fast personalized dosimetry at the whole-body level, yielding results comparable to those of the direct Monte Carlo approach.Keywords
This publication has 21 references indexed in Scilit:
- Study of the Impact of Tissue Density Heterogeneities on 3-Dimensional Abdominal Dosimetry: Comparison Between Dose Kernel Convolution and Direct Monte Carlo MethodsJournal of Nuclear Medicine, 2012
- A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codesMedical Physics, 2012
- Whole-Body Distribution and Radiation Dosimetry of 68 Ga-NOTA-RGD, a Positron Emission Tomography Agent for Angiogenesis ImagingCancer Biotherapy and Radiopharmaceuticals, 2012
- Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeVPhysics in Medicine & Biology, 2011
- A radionuclide dosimetry toolkit based on material-specific Monte Carlo dose kernelsNuclear Medicine Communications, 2009
- MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry—Standardization of NomenclatureJournal of Nuclear Medicine, 2009
- A Monte Carlo approach to patient-specific dosimetryMedical Physics, 1996
- Validation of a dose-point kernel convolution technique for internal dosimetryPhysics in Medicine & Biology, 1995
- Electron-photon Monte Carlo calculations: The ETRAN codeInternational Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, 1991
- Effect of tissue inhomogeneity on dose distribution of point sources of low‐energy electronsMedical Physics, 1990