Respiratory acoustic thoracic imaging (RATHI): Assessing deterministic interpolation techniques
- 1 September 2004
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 42 (5) , 618-626
Abstract
As respiratory sounds contain mechanical and clinical pulmonary information, technical efforts have been devoted during the past decades to analysing, processing and visualising them. The aim of this work was to evaluate deterministic interpolating functions to generate surface respiratory acoustic thoracic images (RATHIs), based on multiple acoustic sensors. Lung sounds were acquired from healthy subjects through a 5×5 microphone array on the anterior and posterior thoracic surfaces. The performance of five interpolating functions, including the linear, cubic spline, Hermite, Lagrange and nearest neighbour method, were evaluated to produce images of lung sound intensity during both breathing phases, at low (∼0.5ls−1) and high (∼1.0ls−1) airflows. Performance indexes included the normalised residual variance nrv (i.e. inaccuracy), the prediction covariance cv (i.e. precision), the residual covariance rcv (i.e. bias) and the maximum squared residual error semax (i.e. tolerance). Among the tested interpolating functions and in all experimental conditions, the Hermite function (nrv=0.146±0.059, cv=0.925±0.030, rcv=−0.073±0.068, semax=0.005±0.004) globally provided the indexes closert to the optimum, whereas the nearest neighbour (nrv=0.339±0.023, cv=0.870±0.033, rcv=0.298±0.032, semax=0.007±0.005) and the Lagrange methods (nrv=0.287±0.148, cv=0.880±0.039, rcv=−0.524±0.135, semax=0.007±0.0001) presented the poorest statistical measurements. It is concluded that, although deterministic interpolation functions indicate different performances among tested techniques, the Hermite interpolation function presents a more confident deterministic interpolation for depicting surface-type RATHI.Keywords
This publication has 29 references indexed in Scilit:
- Survey: interpolation methods in medical image processingIEEE Transactions on Medical Imaging, 1999
- A task-specific evaluation of three-dimensional image interpolation techniquesIEEE Transactions on Medical Imaging, 1999
- An objective comparison of 3-D image interpolation methodsIEEE Transactions on Medical Imaging, 1998
- Interference cancellation in respiratory sounds via a multiresolution joint time-delay and signal-estimation schemeIEEE Transactions on Biomedical Engineering, 1997
- Systematic comparisons of interpolation techniques in topographic brain mappingElectroencephalography and Clinical Neurophysiology, 1993
- A statistical evaluation of the main interpolation methods applied to 3-dimensional EEG mappingElectroencephalography and Clinical Neurophysiology, 1991
- On the comparison of interpolation methodsIEEE Transactions on Medical Imaging, 1988
- New Tools in Lung Sound ResearchSeminars in Respiratory and Critical Care Medicine, 1985
- Lung Sounds as Indices of VentilationSeminars in Respiratory and Critical Care Medicine, 1985
- Visual Lung-Sound Characterization by Time-Expanded Wave-Form AnalysisNew England Journal of Medicine, 1977