Artificial intelligence applications in refractive error management: A systematic review and meta-analysis
Open Access
- 25 September 2025
- journal article
- ophthalmology
- Published by Public Library of Science (PLoS) in PLOS Digital Health
- Vol. 4 (9) , e0000904
Abstract
Artificial intelligence (AI) has transformed healthcare, and is becoming increasingly useful in eye care. We conducted a systematic review and meta-analysis of the use of AI in the diagnosis, detection, prediction, progression, and treatment of refractive errors (REs). The study adhered to the PRISMA checklist to ensure transparent reporting. The following databases were searched from inception to January 2025, with an English language restriction: PubMed, Web of Science, Embase, Scopus, Cochrane Library and Google Scholar. Two independent reviewers performed study screening, data extraction, and quality assessment, with a third author resolving discrepancies. All original studies on the use of AI techniques in RE were identified and the effectiveness of these techniques was compared. A critical appraisal was conducted using the QUADAS-2 risk-of-bias tool. A meta-analysis was performed using R software (version 4.5.0). Of 6,288 records retrieved, 45 met eligibility for systematic review, with 19 included in meta-analysis. Among these 45 studies, 55.5% (25/45) applied deep learning (DL) approaches, while 44.4% (20/45) employed machine learning (ML) techniques. The pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary of receiver operating characteristic (SROC) for detection and/or diagnosis studies were 0.94 (95%CI, 0.90-0.97), 0.96 (95%CI, 0.92-0.98), 382.56 (95% CI 111.91 -1307.77) and 0.98 (95%CI, 0.91-0.97), respectively. For prediction of REs, the pooled sensitivity, specificity, DOR, and SROC were 0.87 (95%CI, 0.73-0.94), 0.96 (95%CI, 0.90-0.980), 159.94 (95% CI, 40.17-636.85) and 0.96 (95%CI, 0.85-0.95), respectively. Among studies focused on progression, performance metrics ranged from AUC = 0.845-0.99, R² = 0.613-0.964, and MAE = 0.119D-0.49D. In treatment studies, performance varied more widely, with AUC values between 0.60–0.94 and MAE from 0.17D-0.54D. Collectively, AI technologies, particularly DL and ML, achieved high diagnostic and predictive accuracy in RE management. Future research should focus on developing generalizable models trained on diverse datasets to ensure broad clinical relevance.Keywords
This publication has 98 references indexed in Scilit:
- Deep Transfer Learning for Ethnically Distinct Populations: Prediction of Refractive Error Using Optical Coherence TomographyOphthalmology and Therapy, 2023
- Deep neural network with self-attention based automated determination system for treatment zone and peripheral steepened zone in Orthokeratology for adolescent myopiaContact Lens and Anterior Eye, 2023
- A machine learning-based algorithm for estimating the original corneal curvature based on corneal topography after orthokeratologyContact Lens and Anterior Eye, 2023
- Artificial Intelligence in Africa: Emerging Challenges2023
- Machine learning algorithm improves accuracy of ortho-K lens fitting in vision shaping treatmentContact Lens and Anterior Eye, 2022
- Outcomes of Adversarial Attacks on Deep Learning Models for Ophthalmology Imaging DomainsJAMA Ophthalmology, 2020
- Artificial Intelligence in Health CareJAMA, 2020
- Development and Validation of a Deep Learning System to Detect Glaucomatous Optic Neuropathy Using Fundus PhotographsJAMA Ophthalmology, 2019
- Development and Validation of a Deep Learning System for Diabetic Retinopathy and Related Eye Diseases Using Retinal Images From Multiethnic Populations With DiabetesJAMA, 2017
- Development and Validation of a Deep Learning Algorithm for Detection of Diabetic Retinopathy in Retinal Fundus PhotographsJAMA, 2016