Empowering Technology Enabled Care Using IoT and Smart Devices: A Review
- 22 December 2017
- journal article
- review article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (5) , 1790-1809
Abstract
Designing power aware wearable devices is the main key to building compact size autonomous smart devices for successful connected health IoT solutions. With their ability to perform tasks ranging from simple self-monitoring to complex interactive tasks, these devices hold great promises in providing a large scale cost effective solution to the challenges facing nowadays healthcare systems. Despite the advances in sensing and hardware design, there still remain several technical challenges facing the research community to build devices that meet the computational requirements with a self-powered capability. Overcoming these challenges require major improvements in all the building blocks of wearable devices including sensors, power management, signal processing, computing architectures and communication. This paper surveys some of the past milestones related to these subsystems and discusses promising research directions addressing their limitations.Keywords
Funding Information
- National Priorities Research Program from the Qatar National Research Fund (a member of Qatar Foundation) (9-114-2-055)
This publication has 126 references indexed in Scilit:
- Wireless Sensor Network Operating System Design Rules Based on Real-World Deployment SurveyJournal of Sensor and Actuator Networks, 2013
- Quantitative analysis of fall risk using TUG testComputer Methods in Biomechanics and Biomedical Engineering, 2013
- A review of wearable sensors and systems with application in rehabilitationJournal of NeuroEngineering and Rehabilitation, 2012
- A 0.013 ${\hbox {mm}}^{2}$, 5 $\mu\hbox{W}$, DC-Coupled Neural Signal Acquisition IC With 0.5 V SupplyIEEE Journal of Solid-State Circuits, 2011
- A proposal for the classification and evaluation of fall detectorsIRBM, 2008
- Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filterPhysiological Measurement, 2007
- A 2 $\mu\hbox{W}$ 100 nV/rtHz Chopper-Stabilized Instrumentation Amplifier for Chronic Measurement of Neural Field PotentialsIEEE Journal of Solid-State Circuits, 2007
- A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition SystemsIEEE Journal of Solid-State Circuits, 2007
- Mems inertial power generators for biomedical applicationsMicrosystem Technologies, 2006
- Superiority of Ambulatory Over Clinic Blood Pressure Measurement in Predicting MortalityHypertension, 2005