Cooling Effectiveness of a Data Center Room under Overhead Airflow via Entropy Generation Assessment in Transient Scenarios
Open Access
Abstract
Forecasting data center cooling demand remains a primary thermal management challenge in an increasingly larger global energy-consuming industry. This paper proposes a dynamic modeling approach to evaluate two different strategies for delivering cold air into a data center room. The common cooling method provides air through perforated floor tiles by means of a centralized distribution system, hindering flow management at the aisle level. We propose an idealized system such that five overhead heat exchangers are located above the aisle and handle the entire server cooling demand. In one case, the overhead heat exchangers force the airflow downwards into the aisle (Overhead Downward Flow (ODF)); in the other case, the flow is forced to move upwards (Overhead Upward Flow (OUF)). A complete fluid dynamic, heat transfer, and thermodynamic analysis is proposed to model the system’s thermal performance under both steady state and transient conditions. Inside the servers and heat exchangers, the flow and heat transfer processes are modeled using a set of differential equations solved in MATLAB™ 2017a. This solution is coupled with ANSYS-Fluent™ 18, which computes the three-dimensional velocity, temperature, and turbulence on the Airside. The two approaches proposed (ODF and OUF) are evaluated and compared by estimating their cooling effectiveness and the local Entropy Generation. The latter allows identifying the zones within the room responsible for increasing the inefficiencies (irreversibilities) of the system. Both approaches demonstrated similar performance, with a small advantage shown by OUF. The results of this investigation demonstrated a promising approach of data center on-demand cooling scenarios.Keywords
Funding Information
- National Science Foundation (IIP-1134810)
- Comisión Nacional de Investigación Científica y Tecnológica (11160172)
This publication has 19 references indexed in Scilit:
- Determining wasted energy in the airside of a perimeter-cooled data center via direct computation of the Exergy DestructionApplied Energy, 2018
- Optimization of data center cooling efficiency using reduced order flow modeling within a flow network modeling approachApplied Thermal Engineering, 2017
- Energy and exergy assessment in a perimeter cooled data center: The value of second law efficiencyApplied Thermal Engineering, 2017
- Rapid prediction of exergy destruction in data centers due to airflow mixingNumerical Heat Transfer, Part A: Applications, 2016
- Simulation of Entropy Generation under Stall Conditions in a Centrifugal FanEntropy, 2014
- The Role of Entropy Generation in Momentum and Heat TransferJournal of Heat Transfer, 2012
- Measurements and predictions of the air distribution systems in high compute density (Internet) data centersEnergy and Buildings, 2009
- Exergy Analysis of Data Center Thermal Management SystemsJournal of Heat Transfer, 2008
- Direct and indirect methods of calculating entropy generation rates in turbulent convective heat transfer problemsHeat and Mass Transfer, 2006
- Local entropy production in turbulent shear flows: a high-Reynolds number model with wall functionsInternational Journal of Heat and Mass Transfer, 2004