Biomechanical Impact of Wrong Positioning of a Dedicated Stent for Coronary Bifurcations: A Virtual Bench Testing Study
- 17 May 2018
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 9 (3) , 415-426
Abstract
The treatment of coronary bifurcations is challenging for interventional cardiologists. The Tryton stent (Tryton Medical, Inc., USA) is one of the few devices specifically designed for coronary bifurcations that underwent large clinical trials. Although the manufacturer provides specific recommendations to position the stent in the bifurcation side branch (SB) according to four radio-opaque markers under angiographic guidance, wrong device positioning may accidentally occur. In this study, the virtual bench testing approach was used to investigate the impact of wrong positioning of the Tryton stent in coronary bifurcations in terms of geometrical and biomechanical criteria. A finite element model of the left anterior descending/first diagonal coronary bifurcation was created with a 45° distal angle and realistic lumen diameters. A validated model of the Tryton stent mounted on stepped delivery balloon was used. All steps of the Tryton deployment sequence were simulated. Three Tryton positions, namely ‘proximal’, ‘recommended’, and ‘distal’ positions, obtained by progressively implanting the stent more distally in the SB, were compared. The ‘recommended’ case exhibited the lowest ostial area stenosis (44.8 vs. 74.3% (‘proximal’) and 51.5% (‘distal’)), the highest diameter at the SB ostium (2.81 vs. 2.70 mm (‘proximal’) and 2.54 mm (‘distal’)), low stent malapposition (9.9 vs. 16.3% (‘proximal’) and 8.5% (‘distal’)), and the lowest peak wall stress (0.37 vs. 2.20 MPa (‘proximal’) and 0.71 MPa (‘distal’)). In conclusion, the study shows that a ‘recommended’ Tryton stent positioning may be required for optimal clinical results.Keywords
This publication has 37 references indexed in Scilit:
- The Tryton Side Branch Stent™ for the treatment of coronary bifurcation lesionsExpert Review of Medical Devices, 2013
- Patient-specific simulations of stenting procedures in coronary bifurcations: Two clinical casesMedical Engineering & Physics, 2013
- Potential Benefit of Final Kissing Balloon Inflation After Single Stenting for the Treatment of Bifurcation LesionsCirculation Journal, 2013
- Modelling of the provisional side-branch stenting approach for the treatment of atherosclerotic coronary bifurcations: effects of stent positioningBiomechanics and Modeling in Mechanobiology, 2010
- A Novel Simulation Strategy for Stent Insertion and Deployment in Curved Coronary Bifurcations: Comparison of Three Drug-Eluting StentsAnnals of Biomedical Engineering, 2009
- Assessment of tissue prolapse after balloon-expandable stenting: Influence of stent cell geometryMedical Engineering & Physics, 2008
- The “Crush” Technique for Coronary Artery Bifurcation Stenting: Insights From Micro-Computed Tomographic Imaging of Bench DeploymentsJACC: Cardiovascular Interventions, 2008
- Restenosis following implantation of bare metal coronary stents: Pathophysiology and pathways involved in the vascular response to injuryAdvanced Drug Delivery Reviews, 2006
- Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modelingAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Bifurcation Coronary Lesions Treated With the “Crush” TechniqueJACC, 2005