Fibrotic Plaque and Microvascular Dysfunction Predict Early Cardiac Allograft Vasculopathy Progression After Heart Transplantation: The Early Post Transplant Cardiac Allograft Vasculopathy Study
Authors:
- Sharon ChihSCSharon Chih
- Aun Yeong ChongACAun Yeong Chong
- Vladimír DžavíkVDVladimír Džavík
- Derek Y. SoDSDerek Y. So
- Natasha AleksovaNANatasha Aleksova
- George A. WellsGWGeorge A. Wells
- Jordan BernickJBJordan Bernick
- Ellamae StadnickESEllamae Stadnick
- Lisa M. MielniczukLMLisa M. Mielniczuk
- Rob S.B. BeanlandsRBRob S.B. Beanlands
- Heather J. RossHRHeather J. Ross
- 1 June 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 16 (6) , e010173
Abstract
Background: Early cardiac allograft vasculopathy (CAV) prognostication is needed to improve long-term outcomes after heart transplantation. We characterized first year posttransplant coronary anatomic-physiologic alterations to determine predictors of early CAV progression.Methods: Heart transplant recipients at 2 institutions (enrolled January 2018 to March 2021) underwent prospective evaluation 3 and 12-month posttransplant with angiography and left anterior descending artery intravascular ultrasound, optical coherence tomography, fractional flow reserve, coronary flow reserve, and index of microcirculatory resistance measurements. CAV progression was assessed by intravascular ultrasound change in percentage intimal volume from baseline to 12-month follow-up.Results: Eighty-two patients (mean age, 51 years; 60% men) completed evaluation at mean 13.8 and 56.3 weeks posttransplant. Donor atherosclerosis (baseline intravascular ultrasound maximal intimal thickness, = 0.5 mm) was evident in 50%. De novo (follow-up maximal intimal thickness, = 0.5 mm) and rapidly progressive CAV (maximal intimal thickness, = 0.5-mm increase from baseline) developed in 24% and 13%, respectively. On optical coherence tomography, baseline to follow-up median intimal volume increased 42% (0.58 mm(3)/mm), percentage intimal volume increased 44% (4.6%), vessel volume decreased 4% (-0.50 mm(3)/mm) and lumen volume decreased 9% (-1.02 mm(3)/mm); P<0.05 for all. Fibrotic plaque was the predominant morphology: baseline, 29% and follow-up, 50%. Coronary physiology was abnormal in 41% at baseline and 45% at follow-up, with 1 in 5 patients having microvascular dysfunction (index of microcirculatory resistance, = 25). On multivariable linear regression analysis, recipient male sex, fibrotic plaque, and index of microcirculatory resistance were independent predictors of coronary disease progression.Conclusions: Fibrotic plaque on optical coherence tomography and index of microcirculatory resistance early posttransplant predict CAV progression in the first year of transplantation.Registration:URL: ; Unique identifier: NCT03217786.Keywords
This publication has 29 references indexed in Scilit:
- Coronary atherosclerosis with vulnerable plaque and complicated lesions in transplant recipients: new insight into cardiac allograft vasculopathy by optical coherence tomographyEuropean Heart Journal, 2013
- Clinical and Functional Correlates of Early Microvascular Dysfunction After Heart TransplantationCirculation: Heart Failure, 2012
- Impact of Donor-Transmitted Atherosclerosis on Early Cardiac Allograft Vasculopathy: New Findings by Three-Dimensional Intravascular Ultrasound AnalysisTransplantation, 2011
- International Society for Heart and Lung Transplantation working formulation of a standardized nomenclature for cardiac allograft vasculopathy—2010The Journal of Heart and Lung Transplantation, 2010
- Prognostic Impact of Microvasculopathy on Survival After Heart TransplantationCirculation, 2007
- Influence of Pre-Existing Donor Atherosclerosis on the Development of Cardiac Allograft Vasculopathy and Outcomes in Heart Transplant RecipientsJACC, 2006
- Invasive Assessment of the Coronary MicrocirculationCirculation, 2006
- Assessment of Coronary Arterial Plaque by Optical Coherence TomographyThe American Journal of Cardiology, 2006
- Multicenter Intravascular Ultrasound Validation Study Among Heart Transplant RecipientsJACC, 2005
- Assessment of Coronary Intima - Media Thickness by Optical Coherence Tomography Comparison With Intravascular UltrasoundCirculation Journal, 2005