Camouflage uncovered: what should happen next?
- 1 March 2023
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 105-B (3) , 221-226
Abstract
Recent publications have drawn attention to the fact that some brands of joint replacement may contain variants which perform significantly worse (or better) than their ‘siblings’. As a result, the National Joint Registry has performed much more detailed analysis on the larger families of knee arthroplasties in order to identify exactly where these differences may be present and may hitherto have remained hidden. The analysis of the Nexgen knee arthroplasty brand identified that some posterior-stabilized combinations have particularly high revision rates for aseptic loosening of the tibia, and consequently a medical device recall has been issued for the Nexgen ‘option’ tibial component which was implicated. More elaborate signal detection is required in order to identify such variation in results in a routine fashion if patients are to be protected from such variation in outcomes between closely related implant types.Cite this article: Bone Joint J 2023;105-B(3):221–226.Keywords
This publication has 20 references indexed in Scilit:
- Tibial tray debonding from the cement mantle is associated with deformation of the backside of polyethylene tibial insertsThe Bone & Joint Journal, 2021
- Implant brand portfolios, the potential for camouflage of data, and the role of the Orthopaedic Data Evaluation Panel in total knee arthroplastyThe Bone & Joint Journal, 2021
- Significant differences in rates of aseptic loosening between two variations of a popular total knee arthroplasty designInternational Orthopaedics, 2021
- Trajectories of pain and function in the first five years after total hip and knee arthroplastyThe Bone & Joint Journal, 2021
- Unexpected high rate of revision of a modern cemented fixed bearing modular posterior-stabilized knee arthroplastyThe Bone & Joint Journal, 2021
- Patellar resurfacing during primary total knee replacement is associated with a lower risk of revision surgeryThe Bone & Joint Journal, 2021
- High rate of tibial debonding and failure in a popular knee replacement: A cause for concernThe Knee, 2020
- Unusually High Rate of Early Failure of Tibial Component in ATTUNE Total Knee Arthroplasty System at Implant–Cement InterfaceThe Journal of Knee Surgery, 2017
- Aseptic Tibial Debonding as a Cause of Early Failure in a Modern Total Knee Arthroplasty DesignClinical Orthopaedics and Related Research, 2013
- Early Aseptic Loosening With a Precoated Low-Profile Tibial ComponentThe Journal of Arthroplasty, 2011