Response of human femur to mechanical vibration
Authors:
- D.Z. LuoDLD.Z. Luo
- 1 January 1991
- journal article
- Published by IOP Publishing in Journal of Biomedical Engineering
- Vol. 13 (1) , 58-60
Abstract
The effect of mechanical vibration in the frequency range 0-500 Hz on the cadaveric human femur was assessed. It was found that when the bone was fixed at both ends, its resonant frequency was markedly affected by end loading and damping. If the conditions of the experiment were designed to simulate the condition of the femur when prepared for a total hip replacement, it was found that the bone did not resonate but behaved in a mass-like mode. The significance of this observation is that in the event of vibration being applied to enhance the penetration of bone cement, the movement induced in the bone will be proportional to the force applied regardless of frequency. This also demonstrates that the concept of designing a prosthesis so that it is isoelastic with the femur is complex and potentially flawed, since the stiffness of the femur will vary during the walking cycle.Keywords
This publication has 3 references indexed in Scilit:
- LOW-FREQUENCY VIBRATION IN APPLICATION OF BONE CEMENTThe Lancet, 1988
- Non-invasive method of measuring the resonant frequency of a human tibia in vivo part 2Journal of Biomedical Engineering, 1987
- Resonance of the Human Tibia:Method, Reproducibility and Effect of TransectionActa Orthopaedica, 1982