Rapid Determination of Clenbuterol in Pork by Direct Immersion Solid-Phase Microextraction Coupled with Gas Chromatography–Mass Spectrometry
Open Access
- 25 August 2015
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 54 (2) , 112-118
Abstract
Direct immersion solid-phase microextraction (DI-SPME) coupled with gas chromatography–mass spectrometry (GC–MS) was developed for rapid analysis of clenbuterol in pork for the first time. In this work, a low-cost homemade 44 µm polydimethylsiloxane (PDMS) SPME fiber was employed to extract clenbuterol in pork. After extraction, derivatization was performed by suspending the fiber in the headspace of the 2 mL sample vial saturated with a vapor of 100 µL hexamethyldisilazane. Lastly, the fiber was directly introduced to GC–MS for analysis. All parameters that influenced absorption (extraction time), derivatization (derivatization reagent, time and temperature) and desorption (desorption time) were optimized. Under optimized conditions, the method offered a wide linear range (10–1000 ng g−1) and a low detection limit (3.6 ng g−1). Finally, the method was successfully applied in the analysis of pork from the market, and recoveries of the method for spiked pork were 97.4–105.7%. Compared with the traditional solvent extraction method, the proposed method was much cheaper and fast.Keywords
Funding Information
- NNSFC (21225731)
- NSF of Guangdong Province (S2013030013474)
- Fundamental Research Funds for the Central Universities (131gjc11)
This publication has 33 references indexed in Scilit:
- Ionic liquids modified dummy molecularly imprinted microspheres as solid phase extraction materials for the determination of clenbuterol and clorprenaline in urineJournal of Chromatography A, 2013
- Selection of a representative matrix for the multiresidue analysis of nine β-agonists in animal tissues and urine with LC-MS/MSThe Analyst, 2013
- Rapid screening of clenbuterol hydrochloride in chicken samples by molecularly imprinted matrix solid-phase dispersion coupled with liquid chromatographyJournal of Chromatography B, 2013
- Matrix effects in the determination of β‐receptor agonists in animal‐derived foodstuffs by ultra‐performance liquid chromatography tandem mass spectrometry with immunoaffinity solid‐phase extractionJournal of Separation Science, 2012
- Simultaneous determination of 10 β2-agonists in swine urine using liquid chromatography–tandem mass spectrometry and multi-walled carbon nanotubes as a reversed dispersive solid phase extraction sorbentJournal of Chromatography A, 2012
- Determination of clenbuterol in porcine tissues using solid-phase extraction combined with ultrasound-assisted dispersive liquid–liquid microextraction and HPLC–UV detectionJournal of Chromatography B, 2011
- Polymer monolith microextraction online coupled to hydrophilic interaction chromatography/mass spectrometry for analysis of β2‐agonist in human urineJournal of Separation Science, 2009
- Determination of clenbuterol in urine using headspace solid phase microextraction or liquid–liquid–liquid microextractionAnalytica Chimica Acta, 2005
- Screening procedures for clenbuterol residue determination in bovine urine and liver matrices using enzyme-linked immunosorbent assay and liquid chromatographyAnalytica Chimica Acta, 2002
- Comparative analytical quantitation of clenbuterol in biological matrices using GC-MS and EIABiomedical Chromatography, 2000