Corneal biomechanics and glaucoma beyond the bidirectional impact of intraocular pressure and corneal deformation response
- 11 May 2022
- journal article
- research article
- Published by Revista Brasileira de Oftalmologia in Revista Brasileira de Oftalmologia
- Vol. 81
Abstract
The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development of [...] ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development ofKeywords
This publication has 46 references indexed in Scilit:
- A New Tonometer—The Corvis ST Tonometer: Clinical Comparison with Noncontact and Goldmann Applanation TonometersInvestigative Ophthalmology & Visual Science, 2013
- Assessment of Corneal Biomechanical Properties in Normal Tension Glaucoma and Comparison With Open-angle Glaucoma, Ocular Hypertension, and Normal EyesJournal of Glaucoma, 2012
- Corneal Biomechanics and BiomaterialsAnnual Review of Biomedical Engineering, 2011
- Multiphoton Microscopy of Ex Vivo Corneas after Collagen Cross-LinkingInvestigative Ophthalmology & Visual Science, 2011
- Characterization of age-related variation in corneal biomechanical propertiesJournal of The Royal Society Interface, 2010
- Effect of Central Corneal Thickness and Corneal Hysteresis on Tonometry as Measured by Dynamic Contour Tonometry, Ocular Response Analyzer, and Goldmann Tonometry in Glaucomatous EyesJournal of Glaucoma, 2008
- Ultrasonic model and system for measurement of corneal biomechanical properties and validation on phantomsJournal of Biomechanics, 2007
- Assessment of Corneal Biomechanical Properties and Their Variation with AgeCurrent Eye Research, 2007
- Central Corneal Thickness and Corneal Hysteresis Associated With Glaucoma DamageAmerican Journal of Ophthalmology, 2006
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005