AutoSet nasal CPAP titration: constancy of pressure, compliance and effectiveness at 8 month follow-up
Authors:
- Aa FarhatAFAa Farhat
- V ExnerVEV Exner
- N KonietzkoNKN Konietzko
- M Berthon-JonesMBM Berthon-Jones
- 1 September 1997
- journal article
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 10 (9) , 2073-2078
Abstract
We have previously shown that AutoSet satisfactorily improves sleep-disordered breathing and sleep architecture in subjects with obstructive sleep apnoea (OSA) syndrome. The aim of this study was to determine, in subjects treated with long-term conventional fixed pressure continuous positive airway pressure (CPAP) at the AutoSet recommended pressure, whether: the long-term compliance is satisfactory; the improvement persists once initial rebound is over; the titration pressure is stable with time; and the titration pressure is comparable with manual titration pressure using a similar end-point. Twenty males with OSA, previously studied with full polysomnography on their diagnostic night, at manual and AutoSet titration, and at the AutoSet recommended fixed pressure, were re-studied after a mean of 3 and 8 months of treatment at the recommended fixed pressure. Re-study included home respiratory monitoring (Nellcor EdenTrace), and repeated manual and AutoSet titration with polysomnography. Compliance was assessed with hour-meter readings. Mean (+/-SEM) usage was 5.7 +/- 0.1 h.night-1 at 3 and 8 months. The arousal index remained normalized. Diagnostic respiratory disturbance index (RDI) was 60.3 +/- 5.7 events.h-1. On AutoSet at fixed CPAP, RDI was initially 2.6 +/- 0.7 events.h-1, then rose slightly (p < 0.001) to 4.3 +/- 0.6 events.h-1 at 3 months, and was 3.6 +/- 0.5 events.h-1 at 8 months. AutoSet titration pressure was: 9.9 +/- 0.4 cmH2O initially, 10.6 +/- 0.4 cmH2O at 3 months, and 9.7 +/- 0.5 cmH2O at 8 months (NS). Manual titration pressure at 8 months was 10.4 +/- 0.4 cmH2O. The standard deviation of the discrepancy with AutoSet was 0.84 cmH2O. In conclusion, the AutoSet recommended pressure varies little with time, and closely predicts the final manual titration pressure; the improvement in respiratory disturbance index was largely maintained, and compliance was good, although probably enhanced by close supervision.Keywords
This publication has 12 references indexed in Scilit:
- Automated Continuous Positive Airway Pressure Titration for Obstructive Sleep Apnea SyndromeAmerican Journal of Respiratory and Critical Care Medicine, 1996
- Frequency of EEG Arousals from Nocturnal Sleep in Normal SubjectsSLEEP, 1995
- Compliance with CPAP therapy in patients with the sleep apnoea/hypopnoea syndrome.Thorax, 1994
- Nasal CPAP: An Objective Evaluation of Patient ComplianceAmerican Journal of Respiratory and Critical Care Medicine, 1994
- Long-Term Compliance With Nasal Continuous Positive Airway Pressure (CPAP) in Obstructive Sleep Apnea Patients and Nonapneic SnorersSLEEP, 1992
- Long-term Acceptance of Continuous Positive Airway Pressure in Obstructive Sleep ApneaAmerican Review of Respiratory Disease, 1991
- Sleep Apnea and Body Position during SleepSLEEP, 1988
- Breathing During Sleep in Normal SubjectsClinics in Chest Medicine, 1985
- OBSTRUCTIVE APNEAS DURING SLEEP IN PATIENTS WITH SEASONAL ALLERGIC RHINITIS1982
- REVERSAL OF OBSTRUCTIVE SLEEP APNOEA BY CONTINUOUS POSITIVE AIRWAY PRESSURE APPLIED THROUGH THE NARESThe Lancet, 1981