Thermal-aware relocation of servers in green data centers
- 6 February 2015
- journal article
- Published by Zhejiang University Press in Frontiers of Information Technology & Electronic Engineering
- Vol. 16 (2) , 119-134
Abstract
Rise in inlet air temperature increases the corresponding outlet air temperature from the server. As an added effect of rise in inlet air temperature, some active servers may start exhaling intensely hot air to form a hotspot. Increase in hot air temperature and occasional hotspots are an added burden on the cooling mechanism and result in energy wastage in data centers. The increase in inlet air temperature may also result in failure of server hardware. Identifying and comparing the thermal sensitivity to inlet air temperature for various servers helps in the thermal-aware arrangement and location switching of servers to minimize the cooling energy wastage. The peak outlet temperature among the relocated servers can be lowered and even be homogenized to reduce the cooling load and chances of hotspots. Based upon mutual comparison of inlet temperature sensitivity of heterogeneous servers, this paper presents a proactive approach for thermal-aware relocation of data center servers. The experimental results show that each relocation operation has a cooling energy saving of as much as 2.1 kW·h and lowers the chances of hotspots by over 77%. Thus, the thermal-aware relocation of servers helps in the establishment of green data centers.Keywords
This publication has 20 references indexed in Scilit:
- Energy-Efficient Thermal-Aware Autonomic Management of Virtualized HPC Cloud InfrastructureJournal of Grid Computing, 2012
- Renewable and cooling aware workload management for sustainable data centersACM SIGMETRICS Performance Evaluation Review, 2012
- Cooling-aware workload placement with performance constraintsPerformance Evaluation, 2011
- Thermal aware workload placement with task-temperature profiles in a data centerThe Journal of Supercomputing, 2011
- Integrating cooling awareness with thermal aware workload placement for HPC data centersSustainable Computing: Informatics and Systems, 2011
- Cooling-aware and thermal-aware workload placement for green HPC data centers2010
- Proactive thermal management in green datacentersThe Journal of Supercomputing, 2010
- Spatio-temporal thermal-aware job scheduling to minimize energy consumption in virtualized heterogeneous data centersComputer Networks, 2009
- Power and performance management of virtualized computing environments via lookahead controlCluster Computing, 2008
- Thermal-aware task scheduling for data centers through minimizing heat recirculation2007