Atrial septal occlusion improves the accuracy of mitral valve area determination following percutaneous mitral balloon valvotomy
Authors:
- 1 January 1991
- journal article
- clinical trial
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 22 (1) , 21-24
Abstract
We investigated the impact of the atrial communication on the mitral valve area calculation after percutaneous mitral balloon valvotomy in 17 patients (15 women, 2 men; mean age 56 ± 4 years). The hemodynamic measurements and mitral valve area calculations were performed with and without balloon occlusion of the atrial septal puncture site. The mitral valve area determined with balloon occlusion was significantly smaller than the mitral valve area determined without occlusion (1.6 ± 0.1 vs. 1.9 ± 0.1 cm2, P < 0.01), and was similar to the echocardiographically determined valve area (1.6 ± 0.1 cm2). This decrease in the calculated mitral valve area with occlusion was associated with a decrease in the measured cardiac output, without a change in the mitral valve gradient or the diastolic filling period. Occlusion of the atrial septal puncture site may permit more accurate determination of the mitral valve area and thus provide a better reference point for future comparison should the question of restenosis arise.Keywords
This publication has 10 references indexed in Scilit:
- Atrial septal defect after percutaneous mitral balloon valvuloplasty: Immediate results and follow-upJACC, 1990
- Assessment of left-to-right atrial shunting after percutaneous mitral valvuloplasty by transesophageal color Doppler flow-mapping.Circulation, 1989
- Results of percutaneous mitral commissurotomy in 200 patientsThe American Journal of Cardiology, 1989
- Follow-up of patients undergoing percutaneous mitral balloon valvotomy. Analysis of factors determining restenosis.Circulation, 1989
- Noninvasive assessment of mitral stenosis before and after percutaneous balloon mitral valvuloplastyThe American Journal of Cardiology, 1988
- Percutaneous balloon valvotomy for patients with severe mitral stenosis.Circulation, 1987
- Percutaneous transvenous balloon valvotomy in a patient with severe calcific mitral stenosisJACC, 1986
- Correlation between cardiac catheterization and echocardiography in assessing the severity of mitral stenosisInternational Journal of Cardiology, 1981
- Blood oxygen measurements in the assessment of intracardiac left to right shunts: A critical appraisal of methodologyThe American Journal of Cardiology, 1980
- Measurement of mitral orifice area in patients with mitral valve disease by real-time, two-dimensional echocardiography.Circulation, 1975