Molecularly Imprinted Polymers for Compound-Specific Isotope Analysis of Polar Organic Micropollutants in Aquatic Environments
- 20 May 2018
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (12) , 7292-7301
Abstract
Compound-specific isotope analysis (CSIA) of polar organic micropollutants in environmental waters requires a processing of large sample volumes to obtain the required analyte masses for analysis by gas chromatography / isotope-ratio mass spectrometry (GC/IRMS). However, the accumulation of organic matter of unknown isotopic composition in standard enrichment procedures currently compromises the accurate determination of isotope ratios. We explored the use of molecularly-imprinted polymers (MIPs) for selective analyte enrichment for 13C/12C and 15N/14N ratio measurements by GC/IRMS using 1H-benzotriazole, a typical corrosion inhibitor in dishwashing detergents, as example of a widely detected polar organic micropollutant. We developed procedures for the treatment of >10 L of water samples, in which custom-made MIPs enabled the selective cleanup of enriched analytes in organic solvents obtained through conventional solid phase extractions. Hydrogen bonding interactions between the traziole moiety of 1H-benzotriazole and the MIP were responsible for selective interactions through an assessment of interaction enthalpies and 15N isotope effects. The procedure was applied successfully without causing isotope fractionation to river water samples as well as in- and effluents of wastewater treatment plants containing µg/L concentrations of 1H-benzotriazole and dissolved organic carbon (DOC) loads of up to 28 mg C/L. MIP-based treatments offer new perspectives for CSIA of organic micropollutants through the reduction of the DOC-to-micropollutant ratios.Keywords
Funding Information
- Schweizerischer Nationalfonds zur F?rderung der Wissenschaftlichen Forschung (CRSII2-141805)
This publication has 62 references indexed in Scilit:
- Critical Evaluation of the 2D-CSIA Scheme for Distinguishing Fuel Oxygenate Degradation Reaction MechanismsEnvironmental Science & Technology, 2012
- pH-Dependent Equilibrium Isotope Fractionation Associated with the Compound Specific Nitrogen and Carbon Isotope Analysis of Substituted Anilines by SPME-GC/IRMSAnalytical Chemistry, 2011
- Molecularly imprinted polymers for sample preparation: A reviewAnalytica Chimica Acta, 2010
- Elimination of Organic Micropollutants in a Municipal Wastewater Treatment Plant Upgraded with a Full-Scale Post-Ozonation Followed by Sand FiltrationEnvironmental Science & Technology, 2009
- Selective trace analysis of diclofenac in surface and wastewater samples using solid-phase extraction with a new molecularly imprinted polymerAnalytica Chimica Acta, 2008
- Compound-Specific Nitrogen and Carbon Isotope Analysis of Nitroaromatic Compounds in Aqueous Samples Using Solid-Phase Microextraction Coupled to GC/IRMSAnalytical Chemistry, 2007
- The Challenge of Micropollutants in Aquatic SystemsScience, 2006
- The Noncovalent Approach2004
- A new concept for isotope ratio monitoring liquid chromatography/mass spectrometryRapid Communications in Mass Spectrometry, 2004
- Factors Controlling Precision and Accuracy in Isotope-Ratio-Monitoring Mass SpectrometryAnalytical Chemistry, 1994