Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurations
- 1 May 2014
- journal article
- research article
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 84 (3) , 541-547
Abstract
Objective: To evaluate how different bracket-slot design characteristics affect the forces released by superelastic nickel-titanium (NiTi) alignment wires at different amounts of wire deflection. Materials and Methods: A three-bracket bending and a classic-three point bending testing apparatus were used to investigate the load-deflection properties of one superelastic 0.014-inch NiTi alignment wire in different experimental conditions. The selected NiTi archwire was tested in association with three bracket systems: (1) conventional twin brackets with a 0.018-inch slot, (2) a self-ligating bracket with a 0.018-inch slot, and (3) a self-ligating bracket with a 0.022-inch slot. Wire specimens were deflected at 2 mm and 4 mm. Results: Use of a 0.018-inch slot bracket system, in comparison with use of a 0.022-inch system, increases the force exerted by the superelastic NiTi wires at a 2-mm deflection. Use of a self-ligating bracket system increases the force released by NiTi wires in comparison with the conventional ligated bracket system. NiTi wires deflected to a different maximum deflection (2 mm and 4 mm) release different forces at the same unloading data point (1.5 mm). Conclusion: Bracket design, type of experimental test, and amount of wire deflection significantly affected the amount of forces released by superelastic NiTi wires ( P < .05). This phenomenon offers clinicians the possibility to manipulate the wire's load during alignment.Keywords
This publication has 23 references indexed in Scilit:
- Load deflection characteristics and force level of nickel titanium initial archwiresThe Angle Orthodontist, 2012
- In vitroevaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignmentThe Korean Journal of Orthodontics, 2012
- Load-deflection characteristics of superelastic and thermal nickel-titanium wiresEuropean Journal of Orthodontics, 2011
- Mechanical properties of coated superelastic archwires in conventional and self-ligating orthodontic bracketsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2010
- Forces released by nonconventional bracket or ligature systems during alignment of buccally displaced teethAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Force Decay of Elastomeric Ligatures: Influence onUnloading Force Compared to Self-LigationThe Angle Orthodontist, 2009
- Forces Produced by Different Nonconventional Bracket or Ligature Systems during Alignment of Apically Displaced TeethThe Angle Orthodontist, 2009
- Load-Deflection Characteristics of Superelastic Nickel-Titanium WiresThe Angle Orthodontist, 2007
- Force-deflection comparison of superelastic nickel-titanium archwiresAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004
- The super-elastic property of the Japanese NiTi alloy wire for use in orthodonticsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1986