Reduction of non-specific binding in immunoassays requiring long incubations
- 31 August 2012
- journal article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 72 (7) , 531-539
Abstract
Despite the studies so far about the non-specific binding of antibody molecule to the plastic of solid phase in enzyme-linked immunoassays, background binding in microwell Elisa continues to be a troublesome problem.Non-specific immunoglobulin from an undiluted serum sample can adhere to the surface of a ‘blocked’ plate to result in a maximal signal in an antigen capture assay for specific antibody to render analysis virtually impossible in undiluted serum when using labelled anti-species antibodies. Yet it is desirable in many circumstances that the maximum sensitivity achievable by the simple expedient of using a concentrated sample (undiluted serum) be exploited, for example in the analysis of antibodies to HIV in the interest of earlier diagnosis. To circumvent this problem we have developed an alternative strategy in which a biotinylated capture reagent is preincubated with the serum sample for the necessary time after which the biotinylated ligand/antibody complex is itself rapidly captured in streptavidin-coated wells at 4°C, with subsequent detection with labelled anti-species immunoglobulin. This manoeuvre enables the capture ligand to be incubated with undiluted serum sample for long time periods resulting in improved specificity of detection. By this means we describe a general method to improve the specificity of serum antibody immunoassays which will be expected to produce the benefit of more rapid diagnosis by signalling antibody production earlier in the abnormal state. Furthermore, our new method could be used to reduce non-specific binding in other immunological assays such as antibody arrays to which much attention has recently been paid.Keywords
This publication has 20 references indexed in Scilit:
- Performance of antibody microarrays fabricated by either DNA-directed immobilization, direct spotting, or streptavidin–biotin attachment: a comparative studyAnalytical Biochemistry, 2004
- Measurement of mouse anti-phospholipid antibodies to solid-phase microspheres by both flow cytofluorometry and Alcian blue-pretreated microtitre plates in an ELISAJournal of Immunological Methods, 1996
- Biotin-avidin immobilization of platelet glycoproteins (BAIPG): a new capture assay for the detection of anti-platelet antibodiesJournal of Immunological Methods, 1995
- Factors affecting the fine specificity and sensitivity of serum antiganglioside antibodies in ELISAJournal of Immunological Methods, 1994
- Effective method for synthetic peptide immobilization that increases the sensitivity and specificity of ELISA proceduresJournal of Immunological Methods, 1992
- Development and applications of ultrasensitive enzyme immunoassays for antigens and antibodiesClinica Chimica Acta, 1989
- α-Fetoprotein antibody-lectin enzyme immunoassay to characterize sugar chains for the study of liver diseasesClinica Chimica Acta, 1989
- A novel enzyme immunoassay of anti-insulin IgG in guinea pig serumBiochemical and Biophysical Research Communications, 1987
- A More Sensitive Enzyme Immunoassay of Anti-Insulin IgG in Guinea Pig Serum with Less Non-Specific Binding of Normal Guinea Pig IgGThe Journal of Biochemistry, 1985
- Use of the enzyme-linked immunosorbent assay for measurement of allergen-specific antibodiesJournal of Immunological Methods, 1985