Relationship between Drain Volume/Fill Volume Ratio and Clinical Outcomes Associated with Overfill Complaints in Peritoneal Dialysis Patients
Authors:
- 1 March 2011
- journal article
- review article
- Published by SAGE Publications in Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis
- Vol. 31 (2) , 148-153
Abstract
Background: To better understand the spectrum of overfill reports and their corresponding clinical severity and etiology, we conducted a review of overfill reports from the Manufacturer and User Facility Device Experience (MAUDE) database, which is within the Food and Drug Administration (FDA) Web site ( www.fda.gov ). Method: We searched the MAUDE database for events related to overfill reports between 1 January 1995 and 31 December 2008 and recorded drain volume (DV)/fill volume (FV), or DV/FV, and clinical symptoms and signs associated with the overfill report. Results: Among 462 MAUDE reports with a possible overfill event, 440 reports (95.2%) with a confirmed overfill event contained sufficient information to ascertain the clinical severity of the event. The number of reports with a clinical severity rating of minor, moderate, major, or death was 331, 71, 28, and 10, respectively. The median (range) DV/FV for a subgroup of 292 reports with a clinical severity rating of minor, moderate, major, or death was 1.63 (1.06 - 4.29), 1.71 (1.08 - 5.87), 2.14(1.64 - 2.61), and 2.50 (2.28 - 3.33), respectively. Insufficient drain accounted for a majority of overfill reports. Conclusion: Our analysis of reports from the MAUDE database suggests an association between DV/FV and clinical severity of the reported overfill event, as well as significant patient-to-patient variability with respect to intra peritoneal volume tolerance.Keywords
This publication has 29 references indexed in Scilit:
- Noninfectious Complications of Peritoneal DialysisJournal of the American Society of Nephrology, 2007
- Dialysate leakage into pericardium in an infant on long-term peritoneal dialysisPediatric Nephrology, 2007
- Intraperitoneal pressure in PD patients: relationship to intraperitoneal volume, body size and PD-related complicationsNephrology Dialysis Transplantation, 2007
- Automated Peritoneal Dialysis Symposium: Intra‐abdominal Pressure, Peritoneal Dialysis Exchange Volume, and Tolerance in APDSeminars in Dialysis, 2002
- Dialysate Leaks in Peritoneal DialysisSeminars in Dialysis, 2001
- Intraperitoneal pressure and hernias in children on peritoneal dialysisPediatric Nephrology, 2000
- The human factors implications of peritoneal dialysis: cycler overfill incident reports.International Journal of Trauma Nursing, 1999
- Effect of posture on intraperitoneal pressure and peritoneal permeability in childrenPediatric Nephrology, 1998
- Acute Hydrothorax in Continuous Ambulatory Peritoneal Dialysis – A Collaborative Study of 161 CentersAmerican Journal of Nephrology, 1989
- High volume, low frequency continuous ambulatory peritoneal dialysisKidney International, 1983