Validation of masks for determination of V̇O 2 max in horses exercising at high intensity
- 21 July 2017
- journal article
- research article
- Published by Wiley in Equine Veterinary Journal
- Vol. 50 (1) , 91-97
Abstract
Summary: Background: The need for a horse to be ridden while wearing a measurement device that allows unrestricted ventilation and gas exchange has hampered accurate measurement of its maximal oxygen consumption (V̇O 2 max) under field conditions. Objectives: Design and validate a facemask with the potential to measure V̇O 2 max accurately in the field. Study design: Experiment with 6 × 6 Latin square design. Methods: Two variations of a mask and associated electronic control module ( ECM ) were designed to enable breath‐by‐breath measurement of airflows through two 7.8 cm diameter pneumotachometers located 7.5 cm in front of each narus. The ECM was comprised of an analogue‐to‐digital converter and a lithium‐ion battery that provided power and signal filtering to the pneumotachometers and an oxygen sensing cell, and powered a pump connected to gas sampling ports between the nares and pneumotachometers. Airflow and oxygen content of inspired and expired gases were recorded through the ECM and electronically transferred to a notebook. V̇O 2 was determined from these recordings using a customised software program. Mask B encased the lower jaw. Mask R left the jaw free so the horse could wear a bit if ridden. V̇O 2 max and arterial blood gases were measured in 6 horses during multiple treadmill tests. Each mask was worn twice and results compared to those from an established open flow‐through system (O) by ANOVA ‐ RM (P2 max (151.9±7.0 [mean±s.d.; O], 151.5±9.6 [B], 149.5±7.5 [R] ml/[kg.min]) were not different between masks. V̇O 2 max measures were reproducible for each mask. Intraclass correlation coefficient between raters = 0.99. Main limitations: Some rebreathing of expired air from mask dead space. Conclusion: Masks capable of measuring V̇O 2 max during treadmill exercise were developed, tested and found to be accurate. Mask R has potential application to measurement of V̇O 2 max under field conditions.Keywords
Funding Information
- Washington State University
This publication has 29 references indexed in Scilit:
- Oxygen consumption and gait variables of Arabian endurance horses measured during a field exercise testEquine Veterinary Journal, 2010
- Evaluation of a mask for breath‐by‐breath respirometry during exercise in horsesEquine Veterinary Journal, 2010
- Circulatory Effects of Splenectomy in the Horse1Zentralblatt für Veterinärmedizin Reihe A, 2010
- Evaluation of oxygen consumption during field exercise tests in Standardbred trottersEquine and Comparative Exercise Physiology, 2007
- Validation of a portable equine metabolic measurement systemEquine Veterinary Journal, 2006
- Validation of the MetaMax II Portable Metabolic Measurement SystemInternational Journal of Sports Medicine, 2004
- Comparison of exercise tests in French trotters under training track, racetrack and treadmill conditionsEquine Veterinary Journal, 1999
- Differences in the ventilatory responses of horses and ponies to exercise of varying intensitiesEquine Veterinary Journal, 1999
- Kinetics of V̇O 2 and V̇CO 2 in the horse and comparison of five methods for determination of maximum oxygen uptakeEquine Veterinary Journal, 1990
- THE PHYSIOLOGICAL MEANING OF THE MAXIMAL OXYGEN INTAKE TEST1Journal of Clinical Investigation, 1958