IOL power calculations after LASIK or PRK: Barrett True-K biometer-only calculation strategy yields equivalent outcomes as a multiple formula approach
- 18 January 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (7) , 784-789
Abstract
Purpose: To compare the accuracy of intraocular lens (IOL) power calculations performed using the biometer-embedded Barrett True-K formula vs a multiple formula approach using the ASCRS postrefractive calculator in eyes with previous myopic or hyperopic refractive surgery. Setting: Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio. Design: Retrospective, consecutive case series. Methods: Patients who underwent cataract surgery with a history of corneal refractive surgery were included. For each formula, the IOL prediction error and refractive prediction error was calculated. Main outcome measures included mean absolute error (MAE) and the percentage of eyes within ±0.25 diopters (D), ±0.50 D, and ±1.00 D. Results: 96 postmyopic eyes and 47 posthyperopic eyes were analyzed. In the postmyopic cohort, the Barrett True-K formula had the lowest MAE (0.36 D), followed by the Haigis-L formula (0.41 D). The Barrett True-K formula had a significantly higher percentage (44.8%) of eyes within ±0.25 D in comparison with the Haigis-L formula (34.4%), which had the second highest percentage (P < .01). In the posthyperopic cohort, the Barrett True-K formula had the lowest MAE (0.41 D), followed by the ASCRS–mean (0.46). The Barrett True-K and ASCRS–mean formulas had the highest percentage of eyes within ±0.25 D (42.6% vs 38.3%, P = .16). Conclusions: The Barrett True-K formula built into the biometer performed equivalently to a multiple formula approach on the ASCRS online calculator in both postmyopic and posthyperopic eyes. This approach reduces the potential for transcription error from data entry for lens power calculation approaches that require manual data entry.Keywords
This publication has 27 references indexed in Scilit:
- Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopiaJournal of Cataract & Refractive Surgery, 2016
- Comparison of Newer Intraocular Lens Power Calculation Methods for Eyes after Corneal Refractive SurgeryOphthalmology, 2015
- New algorithm for intraocular lens power calculations after myopic laser in situ keratomileusis based on rotating Scheimpflug camera dataJournal of Cataract & Refractive Surgery, 2015
- Aiming for emmetropia after cataract surgery: Swedish National Cataract Register studyJournal of Cataract & Refractive Surgery, 2012
- Evaluation of intraocular lens power prediction methods using the American Society of Cataract and Refractive Surgeons Post-Keratorefractive Intraocular Lens Power CalculatorJournal of Cataract & Refractive Surgery, 2010
- Intraocular lens calculation after refractive surgery for myopia: Haigis-L formulaJournal of Cataract & Refractive Surgery, 2008
- Intraocular lens power calculations after refractive surgery: Consensus-K techniqueJournal of Cataract & Refractive Surgery, 2007
- Benchmark standards for refractive outcomes after NHS cataract surgeryEye, 2007
- Comparison of intraocular lens power calculation methods in eyes that have undergone LASIKOphthalmology, 2004
- Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomyOphthalmology, 1999