RADIATION DOSE TO SURGICAL STAFF FROM POSITRON-EMITTER-BASED LOCALIZATION AND RADIOSURGERY OF TUMORS
Authors:
- Elena HeckathorneEHElena Heckathorne
- Colin DimockCDColin Dimock
- Magnus DahlbomMDMagnus Dahlbom
- 1 August 2008
- journal article
- Published by Wolters Kluwer Health in Health Physics
- Vol. 95 (2) , 220-226
Abstract
Surgical tissue characterization based on radiotracer uptake has become much more common in recent years, particularly due to the advent of the sentinel lymph node biopsy technique. Radiolabeled pharmaceuticals are used with hand-held gamma-sensitive probes, which are capable of localizing small tumors and lymph nodes that are first identified via scintigraphy. The radiation safety of such radioguided procedures, which typically employ 99mTc, has been well established. Now, with the emergence of 18F-fluorodeoxyglucose (18FDG) as a widely used tracer for PET imaging of cancer patients, there is increasing interest in the possibility of utilizing 18FDG for intraoperative tumor detection. First, though, the exposure to operating room personnel must be shown to be at a safe level. Due to the short half-life of 18F, the exposure rate will vary significantly with the start time post-injection as well as the duration of the procedure. The aim of this investigation is to determine empirically an exposure rate equation that can be integrated to estimate the exposure to a surgeon and assistants, from patients injected with 18FDG, over an arbitrarily chosen time interval. The study was conducted by measuring the radiation exposure rate from hospital in-patients receiving 18FDG-PET scans at various times from one to seven hours post injection; the empirical equation was determined from the plot of exposure rate vs. time for all patients. The resulting effective dose equivalent for the surgeon for typical values of injected activity, delay time and procedure duration was approximately 60 microSv.Keywords
This publication has 37 references indexed in Scilit:
- The sentinel lymph node: Relevance in gynaecological cancersEuropean Journal of Surgical Oncology, 2006
- Monoclonal antibodies in the treatment of lung cancerEuropean Journal of Surgical Oncology, 2006
- The Role of a Positron- and High-Energy Gamma Photon Probe in Intraoperative Localization of Recurrent MelanomaClinical Nuclear Medicine, 2005
- Current status of dynamic lymphoscintigraphy and sentinel lymph‐node biopsy in urological malignanciesBJU International, 2005
- Laparoscopic resection of occult metastasis using the combination of FDG-positron emission tomography/computed tomography image fusion with intraoperative probe guidance in a woman with recurrent ovarian cancerGynecologic Oncology, 2005
- Radiation protection for the sentinel node procedure in breast cancerEuropean Journal of Surgical Oncology, 2003
- Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET)Radiotherapy and Oncology, 2002
- Application of an [18F]Fluorodeoxyglucose-Sensitive Probe for the Intraoperative Detection of MalignancyJournal of Surgical Research, 2001
- Correlative Whole-Body FDG-PET and Intraoperative Gamma Detection of FDG Distribution in Colorectal CancerClinical Positron Imaging, 2000
- Radiation protection in radioguided surgery of breast cancerNuclear Medicine Communications, 1999