Biomechanical Performance of Total Wrist Arthrodesis Plates With and Without Arthrodesis of the Carpometacarpal Joint
Authors:
Open Access
- 7 October 2023
- journal article
- research article
- Published by SAGE Publications in HAND
- Vol. 20 (2) , 230-236
Abstract
Background: It is unknown whether total wrist arthrodesis (TWA) should be performed with or without arthrodesis of the carpometacarpal joint (CMCJ). The aim of this study is to compare CMCJ-spanning TWA plates using 3D printed wrist arthrodesis model with and without arthrodesis of the CMCJ. Methods: Total wrist arthrodesis plates mounted to 3D printed models were tested under a 4-N bending load at 4 Hz for 50 000 cycles, increased by 15% every 10 000 cycles until failure. Results: Plates with arthrodesis CMCJ were stiffer and failed at a significantly greater load and number of cycles than plates mounted to models without CMCJ arthrodesis. The Synthes stainless steel locking TWA plate performed better than the Trimed plate applied to the model without CMCJ arthrodesis and the Acumed plate applied to the model with CMCJ arthrodesis. Based on these findings, we recommend arthrodesis of the CMCJ in TWA. Conclusions: Incorporation of the CMCJ in TWA may protect against plate failure. If arthrodesis of the CMCJ is not performed, plate removal should be considered before breakage occurs. Level of Evidence: IVKeywords
Funding Information
- medical device companies
This publication has 23 references indexed in Scilit:
- Low-profile locking-plate vs. the conventional AO system: early comparative results in wrist arthrodesisArchives of orthopaedic and trauma surgery, 2019
- Nonspanning Total Wrist Arthrodesis with a Low-Profile Locking PlateJournal of Wrist Surgery, 2017
- Biomechanische Testung einer neuen HandgelenkarthrodesenplatteHandchirurgie · Mikrochirurgie · Plastische Chirurgie, 2015
- Hardware-Related Complications Following Radiocarpal Arthrodesis Using a Dorsal PlateJournal of Wrist Surgery, 2015
- Wrist ArthrodesisHand Clinics, 2005
- Wrist Arthrodesis Using a Synthes Wrist Fusion PlateJournal of Hand Surgery (European Volume), 2003
- AO-wrist arthrodesis: With and without arthrodesis of the third carpometacarpal jointThe Journal of Hand Surgery, 2002
- Wrist Arthrodesis with the AO Titanium Wrist Fusion Plate: A Consecutive Series of 42 CasesJournal of Hand Surgery (European Volume), 2001
- Wrist arthrodesis in post-traumatic arthritis: A comparison of two methodsThe Journal of Hand Surgery, 1993
- Arthrodesis of the Wrist in Rheumatoid Arthritis: A Technique without External FixationScandinavian Journal of Plastic and Reconstructive Surgery, 1971