Spline‐based procedures for dose‐finding studies with active control
Open Access
- 16 October 2014
- journal article
- research article
- Published by Wiley in Statistics in Medicine
- Vol. 34 (2) , 232-248
Abstract
In a dose‐finding study with an active control, several doses of a new drug are compared with an established drug (the so‐called active control). One goal of such studies is to characterize the dose–response relationship and to find the smallest target dose concentrationd*, which leads to the same efficacy as the active control. For this purpose, the intersection point of the mean dose–response function with the expected efficacy of the active control has to be estimated. The focus of this paper is a cubic spline‐based method for deriving an estimator of the target dose without assuming a specific dose–response function. Furthermore, the construction of a spline‐based bootstrap CI is described. Estimator and CI are compared with other flexible and parametric methods such as linear spline interpolation as well as maximum likelihood regression in simulation studies motivated by a real clinical trial. Also, design considerations for the cubic spline approach with focus on bias minimization are presented. Although the spline‐based point estimator can be biased, designs can be chosen to minimize and reasonably limit the maximum absolute bias. Furthermore, the coverage probability of the cubic spline approach is satisfactory, especially for bias minimal designs. © 2014 The Authors.Statistics in MedicinePublished by John Wiley & Sons Ltd.Keywords
This publication has 30 references indexed in Scilit:
- Dose Finding – A Challenge in StatisticsBiometrical Journal, 2008
- Innovative Approaches for Designing and Analyzing Adaptive Dose-Ranging TrialsJournal of Biopharmaceutical Statistics, 2007
- Analysis of Dose–Response Studies—Modeling Approaches2006
- Estimation of the benchmark dose by structural equation modelsBiostatistics, 2006
- Design and Analysis of Dose-Finding Studies Combining Multiple Comparisons and Modeling ProceduresJournal of Biopharmaceutical Statistics, 2006
- Bayesian Model Averaging With Applications to Benchmark Dose Estimation for Arsenic in Drinking WaterJournal of the American Statistical Association, 2006
- Combining Multiple Comparisons and Modeling Techniques in Dose‐Response StudiesBiometrics, 2005
- Multiple Test Procedures for Identifying the Minimum Effective and Maximum Safe Doses of a DrugJournal of the American Statistical Association, 2002
- Dose response studies II. analysis and interpretationJournal of Biopharmaceutical Statistics, 1995
- Dose response studies I. some design considerationsJournal of Biopharmaceutical Statistics, 1995