Effect of Hygrothermal Aging on the Fracture of Composite Overlays on Concrete
Authors:
- 1 March 2002
- journal article
- research article
- Published by SAGE Publications in Journal of Reinforced Plastics and Composites
- Vol. 21 (4) , 293-309
Abstract
This research assessed the effects of elevated temperature and humidity exposures on the durability of fiber reinforced epoxy composite overlays on concrete substrates. Modified double cantilever beam samples were used to determine the Mode I strain energy release rate of the composite-to-concrete bond after exposure to temperatures of 23°, 60° or 100°C, humidity levels of 50 or 95% RH, and times up to 40 days. The only statistically significant degradation in toughness was observed after exposure to the 100°C, 95% RH environment. However, chemical changes in the matrix occurred during this extreme exposure condition that may not represent the in-service aging of composite-repaired concrete structures.Keywords
This publication has 5 references indexed in Scilit:
- The Durability of E-Glass/Vinyl Ester Composite Materials Subjected to Environmental Conditioning and Sustained LoadingJournal of Composite Materials, 1998
- Long-term thermo-oxidative aging in composite materials: Failure mechanismsComposites Science and Technology, 1998
- Investigation of Bond between Concrete and Composites: Use of a Peel TestJournal of Reinforced Plastics and Composites, 1996
- Use of Composites for Rehabilitation of Steel Structures—Determination of Bond DurabilityJournal of Materials in Civil Engineering, 1995
- Effects of fatigue and environment on residual strengths of center-cracked graphite/epoxy buffer strip panelsExperimental Mechanics, 1989