Validation of a novel contact-free heart and respiratory rate monitor
Authors:
- 13 April 2021
- journal article
- research article
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 45 (5) , 344-350
Abstract
There is a growing need for remote monitoring of patients due to a lack of resources and infection control. Current systems use sensors that require constant physical contact with the user, which may result in discomfort or lack of adherence. In the present study, we evaluated the accuracy of a new contact-free system to monitor heart and respiratory rate. Study participants were measured simultaneously using two devices: a contact-free optical system that measures nano-vibrations and movements (investigational device, “Gili Pro BioSensor”) and a standard reference bed-side monitor, inclusive of an electrocardiogram and capnograph modules (Mindray®). Co-primary endpoints included HR and RR accuracy in subjects without active arrhythmias for HR, and for all study populations for RR (i.e., for subjects with and without active arrhythmias). Confirmatory secondary endpoints included HR scored continuously for all study populations, inclusive of subjects with arrhythmias. The present study included 115 patients who completed study procedures. Mean age was 66 ± 14.6 (range 29–93) with 60% males, 31% obese patients (i.e., BMI > 30 kg/m2, range 17–44) and 56% measured in a chair. For the dichotomised accuracy analysis, both co-primary endpoint for HR and RR resulted in 100% accuracy (95% CI: HR 98.8–100%; RR 98.9–100%), whereas for the confirmatory secondary analysis, 99.1% of the HR measurements across subjects with and without active arrhythmias were deemed accurate (95% CI: 97.4–99.8%). The current study demonstrated over 99% accuracy in detecting heart and respiratory rate using a novel contact-free optical system.Keywords
Funding Information
- Donisi Health
This publication has 19 references indexed in Scilit:
- Mass Screening for Untreated Atrial FibrillationCirculation, 2015
- Long-term monitoring of respiratory rate in patients with heart failure: the Multiparametric Heart Failure Evaluation in Implantable Cardioverter-Defibrillator Patients (MULTITUDE-HF) studyJournal of Interventional Cardiac Electrophysiology, 2015
- Demonstration of a Remote Optical Measurement Configuration That Correlates With Breathing, Heart Rate, Pulse Pressure, Blood Coagulation, and Blood OxygenationProceedings of the IEEE, 2015
- Surface Chest Motion Decomposition for Cardiovascular MonitoringScientific Reports, 2014
- Do Active Surveillance and Contact Precautions Reduce MRSA Acquisition? A Prospective Interrupted Time SeriesPLOS ONE, 2013
- Contactless Detection and Analysis of Human Vital Signs Using Concurrent Dual-Band RF SystemProcedia Engineering, 2013
- Simultaneous remote extraction of multiple speech sources and heart beats from secondary speckles patternOptics Express, 2009
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Optical Vibrocardiography: A Novel Tool for the Optical Monitoring of Cardiac ActivityAnnals of Biomedical Engineering, 2006
- Tachycardia exacerbates abnormal left ventricular?arterial coupling in heart failureHeart and Vessels, 2003