Differences in Bio-incompatibility among Four Biocompatible Dialyzer Membranes Using in Maintenance Hemodialysis Patients
Authors:
- 15 June 2011
- journal article
- research article
- Published by Taylor & Francis in Renal Failure
- Vol. 33 (7) , 682-691
Abstract
Background: Following the introduction of modified cellulosic and then synthetic membrane dialyzers, it was realized that the dialyzer bio-incompatibility depends on the membrane composition. We designed a prospective, randomized, cohort study of 6 months to determine several parameters of biocompatibility in maintenance hemodialysis (MHD) patients treated with four different membrane dialyzers. Methods: There were 60 MHD patients enrolled in the study. In baseline, synthetic low-flux dialyzer, polysulfone (PS) membrane was used in all patients for at least 3 months. Then the patients were randomly divided into three groups according to different dialyzer membranes. Synthetic high-flux dialyzer group, ployethersulfone membrane, cellulose triacetate (CTA) high-flux membrane, and synthetic low-flux dialyzer, polymethylmethacrylate (PMMA) membrane were used in 6 months. A new dialyzer was used for each study treatment, and there was no dialyzer reuse. The biocompatibility markers and solutes removal markers were detected repeatedly at different time points. Results: The blood levels of highly sensitive C reactive protein, interleukin (IL)-1β, and interleukin (IL)-13 showed no difference among different groups at al time points. However, the blood complement levels and white blood cell counts were significantly different among three groups. When the dialyzers changed from PS to PMMA membrane, C3a levels and white blood cell counts changed significantly (p < 0.05). Moreover, the changes of C5a levels were significantly different between group CTA and group PMMA in month 3 (p < 0.05). Conclusion: There were much more differences on bio-incompatibility among different dialyzer membranes.Keywords
This publication has 20 references indexed in Scilit:
- Membrane Materials for Blood Purification in Critical Care2010
- Effect of Membrane Permeability on Survival of Hemodialysis PatientsJournal of the American Society of Nephrology, 2009
- A New Synthetic Dialyzer With Advanced Permselectivity for Enhanced Low‐molecular Weight Protein RemovalArtificial Organs, 2008
- Plasma Dimethylarginine Levels in Chronic Hemodialysis Patients Are Independent of the Type of Dialyzer AppliedBlood Purification, 2007
- No Benefit of Hemodiafiltration over Hemodialysis in Lowering Elevated Levels of Asymmetric Dimethylarginine in ESRD PatientsBlood Purification, 2006
- Does an alteration of dialyzer design and geometry affect biocompatibility parameters?Hemodialysis International, 2006
- Intradialytic complications during hemodialysisHemodialysis International, 2006
- Cerebrovascular Disease in Maintenance Hemodialysis Patients: Results of the HEMO StudyAmerican Journal of Kidney Diseases, 2006
- Low dialysance of asymmetric dimethylarginine (ADMA) - in vivo and in vitro evidence of significant protein bindingClinical Nephrology, 2004
- Effects of ultrapure dialysis fluid on nutritional status and inflammatory parametersNephrology Dialysis Transplantation, 2001