Predicting subjective judgment of best focus with objective image quality metrics
Authors:
Open Access
- 1 April 2004
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 4 (4) , 7
Abstract
Purpose: To determine the impact of higher-order monochromatic aberrations on lower-order subjective sphero-cylindrical refractions. Methods: Computationally-aberrated, monochromatic Sloan letters were presented on a high luminance display that was viewed by an observer through a 2.5mm pupil. Through-focus visual acuity (VA) was determined in the presence of spherical aberration (Z40) at three levels (0.10, 0.21 and 0.50D). Analogous through-astigmatism experiments measured visual acuity in the presence of secondary astigmatism (Z4±2) or coma (Z3−1). Measured visual acuity was correlated with 31 different metrics of image quality to determine which metric best predicts performance for degraded retinal images. The defocus and astigmatism levels that optimized each metric were compared with those that produced best visual acuity to determine which metric best predicts subjective refraction. Results: Spherical aberration, coma and secondary astigmatism all reduced VA and increased depth of focus. The levels of defocus and primary astigmatism that produced the best performance varied with levels of spherical aberration and secondary astigmatism, respectively. The presence of coma, however, did not affect cylindrical refraction. Image plane metrics, especially those that take into account the neural contrast sensitivity threshold (e.g. the visual Strehl ratio, VSOTF), are good predictors of visual acuity in both the through-focus and through-astigmatism experiments (R = −0.822 for VSOTF). Subjective sphero-cylindrical refractions were accurately predicted by some image-quality metrics (e.g., pupil fraction, VSOTF and standard deviation of PSF light distribution). Conclusion: Subjective judgment of best focus does not minimize RMS wavefront error (Zernike defocus = 0), nor create paraxial focus (Seidel defocus = 0), but makes the retina conjugate to a plane between these two. It is possible to precisely predict subjective sphero-cylindrical refraction for monochromatic light using objective metrics.Keywords
This publication has 15 references indexed in Scilit:
- Test–Retest Reliability of Clinical Shack-Hartmann MeasurementsInvestigative Ophthalmology & Visual Science, 2004
- Validation of a Clinical Shack-Hartmann AberrometerOptometry and Vision Science, 2003
- Visual Acuity as a Function of Zernike Mode and Level of Root Mean Square ErrorOptometry and Vision Science, 2003
- A Method to Predict Refractive Errors from Wave Aberration DataOptometry and Vision Science, 2003
- Ocular wave-front aberration statistics in a normal young populationVision Research, 2002
- The Repeatability of Automated and Clinician RefractionOptometry and Vision Science, 1998
- Subjective Depth-of-Focus of the EyeOptometry and Vision Science, 1997
- Effects of Spherical and Astigmatic Defocus on Acuity and Contrast Sensitivity: A Comparison of Three Clinical ChartsOptometry and Vision Science, 1991
- A Study of Night MyopiaJournal of the Optical Society of America, 1951
- The Spherical Aberration of the EyeJournal of the Optical Society of America, 1949