The application of novel 1.7 μm ethylene bridged hybrid particles for hydrophilic interaction chromatography
- 23 May 2008
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 31 (9) , 1511-1518
Abstract
An un‐derivatized 1.7 μm ethylene bridged hybrid (BEH) particle was evaluated for its utility in retaining polar species in hydrophilic interaction chromatography (HILIC), and was compared to a 3 μm un‐derivatized silica material. Retentivity as a function of mobile phase pH, polar modifier and ACN content was examined. Also, the efficiency of the two particle substrates was compared by plotting HETP vs. linear velocity. Improved chemical resistance of the un‐derivatized BEH particle was compared to un‐derivatized silica at pH 5, demonstrating no performance deterioration over the course of 2000 injections for the BEH particle, while the silica particle deteriorated rapidly after 800 injections. Lastly, ESI‐MS sensitivity as a function of particle size and separation mode was demonstrated. A 2.2 to 4.7‐times higher ESI‐MS response was observed on the 1.7 μm particle compared to the 3 μm particle, whereas a 5.6 to 8.8‐times higher ESI‐MS response was observed using HILIC as when compared to traditional RP chromatography.Keywords
This publication has 23 references indexed in Scilit:
- Recent advances in high-throughput quantitative bioanalysis by LC–MS/MSJournal of Pharmaceutical and Biomedical Analysis, 2007
- Hydrophilic interaction chromatographyJournal of Separation Science, 2006
- Porous Hybrid Organic‐Inorganic Particles in Reversed‐Phase Liquid ChromatographyJournal of Liquid Chromatography & Related Technologies, 2006
- High‐throughput quantification for a drug mixture in rat plasma – a comparison of Ultra Performance™ liquid chromatography/tandem mass spectrometry with high‐performance liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Advancing LC Performance with Smaller Particles and Higher PressureAnalytical Chemistry, 2005
- Improving LC–MS sensitivity through increases in chromatographic performance: Comparisons of UPLC–ES/MS/MS to HPLC–ES/MS/MSJournal of Chromatography B, 2005
- UPLC™: An Introduction and ReviewJournal of Liquid Chromatography & Related Technologies, 2005
- Characterization and Evaluation of C18 HPLC Stationary Phases Based on Ethyl-Bridged Hybrid Organic/Inorganic ParticlesAnalytical Chemistry, 2003
- Hydrophilic Interaction Chromatography−Electrospray Mass Spectrometry Analysis of Polar Compounds for Natural Product Drug DiscoveryAnalytical Chemistry, 1998
- Separation of organic amine compounds on silica gel with reversed-phase eluentsAnalytical Chemistry, 1982