Validation of the CoaguChek XS international normalised ratio point-of-care analyser in patients at Charlotte Maxeke Johannesburg Academic Hospital, South Africa
Open Access
- 3 February 2016
- journal article
- Published by South African Medical Association NPC in South African Medical Journal
- Vol. 106 (3) , 280-3
Abstract
Background. Measurement of the international normalised ratio (INR) is essential in the management of patients on long-term warfarin therapy. The CoaguChek XS portable coagulometer is a point-of-care test for INR measurement. It offers the advantage of improved patient accessibility, particularly in peripheral clinics. Objectives. To evaluate the clinical utility of the CoaguChek XS for monitoring of patients on standard warfarin therapy (INR 2 - 3) as well as those with mechanical heart valve replacements (INR 2.5 - 3.5). Methods. We compared the performance of the CoaguChek XS device with that of the STAGO laboratory analyser with regard to accuracy and precision in 304 patients referred for routine testing. Results. The mean INR value of the CoaguChek XS of 2.75 (standard deviation (SD) 1.18) was comparable to that of the STAGO (2.65 (SD 1.04)). The Bland-Altman difference plot revealed good agreement. Bias between the two methods was small, and the imprecision was within acceptable limits. Within the target range (2.0 - 3.5), 93.9% of the CoaguChek XS INR readings were within 0.5 units of the standard laboratory method result. There was, however, an increase in the variability of the differences between the two test methods when the INR was >3.6. Conclusion. The CoaguChek XS point-of-care device can be used to provide accurate and precise INR measurements over a wide range for monitoring of valvular and non-valvular patients on long-term warfarin therapy.Keywords
This publication has 14 references indexed in Scilit:
- The reliability of point‐of‐care prothrombin time testing. A comparison of CoaguChek S® and XS® INR measurements with hospital laboratory monitoringInternational Journal of Laboratory Hematology, 2010
- Accuracy and clinical usefulness of the CoaguChek S and XS Point of Care devices when starting warfarin in a hospital outreach settingThrombosis Research, 2009
- Validation of the international normalized ratio (INR) in a new point‐of‐care system designed for home monitoring of oral anticoagulation therapyInternational Journal of Laboratory Hematology, 2009
- International normalised ratio (INR) measured on the CoaguChek S and XS compared with the laboratory for determination of precision and accuracyThrombosis and Haemostasis, 2009
- Results of the performance verification of the CoaguChek XS systemThrombosis Research, 2008
- Accuracy of Capillary Whole Blood International Normalized Ratio on the CoaguChek S, CoaguChek XS, and i-STAT 1 Point-of-Care AnalyzersAmerican Journal of Clinical Pathology, 2008
- Influence of haematocrit on international normalised ratio (INR) differences between a whole blood point-of-care coagulation monitor and reference prothrombin time in plasmaThrombosis and Haemostasis, 2008
- INR comparison between the CoaguChek® S and a standard laboratory method among patients with self-management of oral anticoagulationThrombosis Research, 2007
- Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoringJournal of Clinical Pathology, 2006
- Point-of-care testing of the international normalized ratio in patients with antiphospholipid antibodiesThrombosis and Haemostasis, 2005