Implementation of Fractional-order Integral-plus-proportional Controller to Enhance the Power Quality of an Electrical Grid
- 9 May 2016
- journal article
- research article
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 44 (9) , 1018-1028
Abstract
This article integrates a suitable controller to the direct power control algorithm for a shunt active power filter. The conventional proportional-integral (PI) controller is commonly used in DC bus regulation loops because of its advantages in the steady state, but it is limited in the dynamic state. Thus, this article contributes an appropriate controller, the fractional-order–integral-plus-proportional controller. The controller under study extends the integration order of the controller from integer to real order based on fractional calculus theory and Oustaloup continuous approximation. The fractional-order–integral-plus-proportional controller offers a short response time, withstands parameters variations, and deals with external disturbances. To investigate the efficiency and accuracy of the proposed fractional-order–direct power control algorithm considering all robustness tests, an experimental setup was made. The experimental results confirm its high performance in both steady and dynamic states and demonstrate its feasibility and effectiveness. Therefore, the shunt active power filter improves the power quality, corrects the power factor, and reduces the harmonics injected by non-linear loads. Thanks to its high level of power quality, the fractional-order–direct power control could become an interesting alternative for active power filtering.Keywords
This publication has 27 references indexed in Scilit:
- Direct power control of shunt active filter using high selectivity filter (HSF) under distorted or unbalanced conditionsElectric Power Systems Research, 2014
- Improved Direct Power Control for Rectifier Based on Fuzzy Sliding ModeIEEE Transactions on Control Systems Technology, 2013
- Enhanced robust fractional order proportional-plus-integral controller based on neural network for velocity control of permanent magnet synchronous motorISA Transactions, 2013
- Power quality improvement using DPC controlled three-phase shunt active filterElectric Power Systems Research, 2010
- DPC controlled three-phase active filter for power quality improvementInternational Journal of Electrical Power & Energy Systems, 2008
- A method for modelling and simulation of fractional systemsSignal Processing, 2003
- A note on time-domain simulation of feedback fractional-order systemsIEEE Transactions on Automatic Control, 2002
- Virtual-flux-based direct power control of three-phase PWM rectifiersIEEE Transactions on Industry Applications, 2001
- Direct power control of PWM converter without power-source voltage sensorsIEEE Transactions on Industry Applications, 1998
- Update of harmonic standard IEEE-519: IEEE recommended practices and requirements for harmonic control in electric power systemsIEEE Transactions on Industry Applications, 1989