Aim: Even though TIVADs have been implanted for a long time, immediate complications are still occurring. The aim of this work was to review different techniques of placing TIVAD implants to evaluate the aetiology of immediate complications. Methods: A systematic literature review was performed using the PubMed, Cochrane and Google Scholar databases in accordance with the PRISMA guidelines. The patient numbers, number of implanted devices, specialists involved, implant techniques, implant sites and immediate complication onsets were studied. Results: Of the 1256 manuscripts reviewed, 36 were eligible for inclusion in the study, for a total of 17,388 patients with equivalent TIVAD implantation. A total of 2745 patients (15.8%) were treated with a surgical technique and 14,643 patients (84.2%) were treated with a percutaneous technique. Of the 2745 devices (15.8%) implanted by a surgical technique, 1721 devices (62.7%) were placed in the cephalic vein (CFV). Of the 14,643 implants (84.2%) placed with a percutaneous technique, 5784 devices (39.5%) were placed in the internal jugular vein (IJV), and 5321 devices (36.3%) were placed in the subclavian vein (SCV). The number of immediate complications in patients undergoing surgical techniques was 32 (1.2%) HMMs. In patients treated with a percutaneous technique, the number of total complications were 333 (2.8%): 71 PNX (0.5%), 2 HMT (0.01%), 175 accidental artery punctures AAP (1.2%) and 85 HMM (0.6%). No mortality was reported with either technique. Conclusion: The percutaneous approach is currently the most commonly used technique to implant a TIVAD, but despite specialist’s best efforts, immediate complications are still occurring. Surgical cut-down, 40 years after the first implant, is still the only technique that can avoid all of the immediate complications that can be fatal.Keywords
Funding Information
- Università degli Studi di Catania
This publication has 56 references indexed in Scilit:
- Conversion From Cephalic Vein to External Jugular VeinSurgical Innovation, 2013
- Percutaneous image-guided implantation of totally implantable venous access ports in the forearm or the chest? A patients’ point of viewSupportive Care in Cancer, 2012
- Totally implantable venous access port systems and risk factors for complications: A one-year prospective study in a cancer centreEuropean Journal of Surgical Oncology, 2011
- Insertion of Totally Implantable Venous Access DevicesAnnals of Surgery, 2011
- Outcome of cephalic vein cut-down approach: A safe and feasible approach for totally implantable venous access device placementOncology Letters, 2010
- Complication Rates and Outcomes of 536 Implanted Subcutaneous Chest PortsAcademic Radiology, 2010
- Increased Use of Percutaneous Technique for Totally Implantable Venous Access Devices. Is It Real Progress? A 27-Year Comprehensive Review on Early ComplicationsAnnals of Surgical Oncology, 2010
- Randomized clinical trial of a modified Seldinger technique for open central venous cannulation for implantable access devicesBritish Journal of Surgery, 2009
- External Jugular Vein Cutdown Approach, as a Useful Alternative, Supports the Choice of the Cephalic Vein for Totally Implantable Access Device PlacementAnnals of Surgical Oncology, 2005
- Catheter Replacement of the Needle in Percutaneous Arteriography: A new techniqueActa Radiologica, 1953