Deep learning segmentation for optical coherence tomography measurements of the lower tear meniscus
- 20 February 2020
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (3) , 1539-1554
Abstract
The tear meniscus contains most of the tear fluid and therefore is a good indicator for the state of the tear film. Previously, we used a custom-built optical coherence tomography (OCT) system to study the lower tear meniscus by automatically segmenting the image data with a thresholding-based segmentation algorithm (TBSA). In this report, we investigate whether the results of this image segmentation algorithm are suitable to train a neural network in order to obtain similar or better segmentation results with shorter processing times. Considering the class imbalance problem, we compare two approaches, one directly segmenting the tear meniscus (DSA), the other first localizing the region of interest and then segmenting within the higher resolution image section (LSA). A total of 6658 images labeled by the TBSA were used to train deep convolutional neural networks with supervised learning. Five-fold cross-validation reveals a sensitivity of 96.36% and 96.43%, a specificity of 99.98% and 99.86% and a Jaccard index of 93.24% and 93.16% for the DSA and LSA, respectively. Average segmentation times are up to 228 times faster than the TBSA. Additionally, we report the behavior of the DSA and LSA in cases challenging for the TBSA and further test the applicability to measurements acquired with a commercially available OCT system. The application of deep learning for the segmentation of the tear meniscus provides a powerful tool for the assessment of the tear film, supporting studies for the investigation of the pathophysiology of dry eye-related diseases.Keywords
Funding Information
- Christian Doppler Forschungsgesellschaft
- Bundesministerium für Digitalisierung und Wirtschaftsstandort
- Österreichische Nationalstiftung für Forschung, Technologie und Entwicklung
- Carl Zeiss
This publication has 24 references indexed in Scilit:
- Repeatability of tear meniscus evaluation using spectral-domain Cirrus® HD-OCT and time-domain Visante® OCTContact Lens and Anterior Eye, 2015
- In vivo tear film thickness measurement and tear film dynamics visualization using spectral domain optical coherence tomographyOptics Express, 2015
- Measurement of Tear Film Thickness Using Ultrahigh-Resolution Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2013
- Tear Meniscus Evaluation by Anterior Segment Swept-Source Optical Coherence TomographyAmerican Journal of Ophthalmology, 2013
- Tear meniscus measurement in nasolacrimal duct obstruction patients with Fourier‐domain optical coherence tomography: novel three‐point capture methodActa Ophthalmologica, 2011
- Reproducibility of Tear Meniscus Measurement by Fourier-Domain Optical Coherence Tomography: A Pilot StudyOphthalmic Surgery, Lasers and Imaging Retina, 2009
- Etiology, prevalence, and treatment of dry eye diseaseClinical Ophthalmology, 2009
- Noninvasive Interference Tear Meniscometry in Dry Eye Patients With Sjögren SyndromeAmerican Journal of Ophthalmology, 2007
- Relationship Between Tear Volume and Tear Meniscus CurvatureArchives of Ophthalmology (1950), 2004
- The Height and Radius of the Tear Meniscus and Methods for Examining These ParametersCornea, 2000