The effect of different knee angles on knee volume measured with the Perometer® device in uninjured subjects*
Authors:
- 17 March 2003
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 23 (2) , 114-119
Abstract
Summary: The Perometer® is an optoelectronic device used to calculate limb volume. However, knee angle effect on knee volume during a Perometer measurement has not been reported. This could be a potential confounding factor in assessing knee volume in subjects with impaired knee mobility and where volume measurements are taken over time. To address this issue, bilateral knee volume measurements were recorded from 20 uninjured subjects in seven different knee angles from 0–60° flexion. All 40 knees were not measured in all seven angles because of obstruction of the measurement frame when some knees were in 50° and 60° flexion. Thus, the volume data was separated into three subgroups for analysis: 40 knees at knee flexion angles 0, 10, 20, 30 and 40°; 36 knees at 50°; and 16 knees at 60°. Repeated measures analysis of variance showed a statistically significant difference between the volume measurements in the three subgroups: 0–40° knee flexion [F(4,156) = 35·146, PF(5,175) = 56·826, PF(6,90) = 45·825, Pt‐tests showed statistically significant [PP = 0·772) and 0 and 20° (absolute volume difference of 10·9 ml; P = 0·036) (Bonferroni adjustment applied). The absolute values of the differences that were shown to be statistically significantly different ranged from 12–47 ml for the 0–40° subgroup; 39–85 ml for the 50° subgroup and 35–107 ml for the 60° subgroup. In conclusion, knee angle affects Perometer knee volume measurements and statistically significant differences occur as knee flexion exceeds 20° with greater differences occurring as the knee is more flexed. Hence, knee angle should be reproduced in re‐testing and in side‐to‐side comparisons when evaluating knee volume with the Perometer.Keywords
This publication has 7 references indexed in Scilit:
- Edema and Leg Volume: Methods of AssessmentAngiology, 2000
- Volumetric measurements of peripheral oedema in clinical conditionsClinical Physiology and Functional Imaging, 2000
- Infrared optoelectronic volumetry, the ideal way to measure limb volumeEuropean Journal of Vascular and Endovascular Surgery, 1996
- Lower Limb Volume Measurements: Standardization and Reproducibility of an Adapted Optical Leg Volume MeterPhlebology: The Journal of Venous Disease, 1993
- Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreementJournal of Biomedical Engineering, 1993
- Intraclass correlations: Uses in assessing rater reliability.Psychological Bulletin, 1979
- Intraclass correlations: Uses in assessing rater reliability.Psychological Bulletin, 1979