Influence of Parameters on Root Surface Roughness Following Treatment With a Magnetostrictive Ultrasonic Scaler: An In Vitro Study
Authors:
- Matthias FolwacznyMFMatthias Folwaczny
- Ute MerkelUMUte Merkel
- Albert MehlAMAlbert Mehl
- Reinhard HickelRHReinhard Hickel
- 1 September 2004
- journal article
- clinical trial
- Published by Wiley in Journal of Periodontology
- Vol. 75 (9) , 1221-1226
Abstract
Background: This in vitro study aimed to evaluate the influence of different parameters, i.e., lateral force, instrument power setting, and the shape of the working tip, on the roughness of root surfaces following treatment with a magnetostrictive ultrasonic scaling device.Methods: The study sample comprised a total of 102 extracted human molars, premolars, canines, and incisors. The samples were randomly divided into 10 equal units of 10 each for treatment with the ultrasonic device at a lateral force of 0.5 N and 2.0 N, low and high instrument power setting, and with a straight and angulated shaped working tip. Twenty samples were treated manually using curets at a lateral force of 0.5 N and 2.0 N. Two samples were left untreated as controls. The mean (Ra) and maximum (Rmax) surface roughness of each sample was recorded. The statistical analysis was performed using analysis of variance (three‐way ANOVA) at a level of significance of 5% (P Results: The mean surface roughness (±SD) using different parameters ranged from 0.6 ± 0.1 μm to 1.8 ± 0.3 μm. The maximum surface roughness (±SD) was between 4.8 ± 1.3 μm and 17.2 ± 4.3 μm. The mean surface roughness (±SD) for samples treated with curets at a lateral force of 0.5 N was 0.5 ± 0.0 μm and 0.4 ± 0.1 μm at 2.0 N. The maximum surface roughness (±SD) was 3.7 ± 0.8 μm at 0.5 N and 3.9 ± 1.4 μm at 2.0 N.Conclusions: The findings of the present study indicate that the shape of the working tip and the lateral force significantly influence the mean and maximum surface roughness of root surfaces treated with a magnetostrictive ultrasonic scaling device. At any specific parameter, the surface roughness was signifi‐ cantly higher for the ultrasonic scaling device as compared to the hand curet. J Periodontol 2004;75:1221‐1226.Keywords
This publication has 24 references indexed in Scilit:
- Effect of surface roughness of porcelain on adhesion of bacteria and their synthesizing glucansThe Journal of Prosthetic Dentistry, 2000
- Working parameters of a sonic scaler influencing root substance removal in vitroClinical Oral Investigations, 1997
- The influence of abutment surface roughness on plaque accumulation and peri‐implant mucositisClinical Oral Implants Research, 1996
- Variability of sonic scaling tip movementJournal of Clinical Periodontology, 1994
- On the prevention of caries and periodontal diseaseJournal of Clinical Periodontology, 1991
- In vivo early human dental plaque formation on different supporting substances. A scanning electron microscopic and bacteriological study.Clinical Oral Implants Research, 1991
- Surface‐free energy and bacterial adhesionJournal of Clinical Periodontology, 1987
- An evaluation of basic periodontal therapy using sonic and ultrasonic sealersJournal of Clinical Periodontology, 1987
- Inherent variability of the performance of the ultrasonic descalerJournal of Dentistry, 1986
- Effect of nonsurgical periodontal therapyJournal of Clinical Periodontology, 1984