Thermal Analysis of As-received and Clinically Retrieved Copper-nickel-titanium Orthodontic Archwires
Authors:
- David W. BerzinsDBDavid W. Berzins
- Thomas Gerard BradleyTBThomas Gerard Bradley
- 1 May 2007
- journal article
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 77 (3) , 499-503
Abstract
To compare as-received copper-nickel-titanium (CuNiTi) archwires to those used in patients by means of differential scanning calorimetry (DSC). Also, the thermal or phase properties of 27 degrees C, 35 degrees C, and 40 degrees C CuNiTi archwires were studied to ascertain if their properties match those indicated by the manufacturer. Six wires of 27 degrees C, 35 degrees C, and 40 degrees C CuNiTi were tested as-received, and six each of the 27 degrees C and 35 degrees C wires were examined after use in patients for an average of approximately 9 and 7 weeks, respectively. Segments of archwire were investigated by DSC over the temperature range from -100 degrees C to 150 degrees C at 10 degrees C per minute. There were no significant differences between as-received and clinically used 27 degrees C and 35 degrees C wires for all parameters (heating onset, endset, and enthalpy and cooling onset, endset, and enthalpy), except the 27 degrees C wires exhibited a significant decrease in the heating enthalpy associated with the martensite-to-austenite transition after clinical use. The heating endsets (austenite finish temperatures) of the 27 degrees C and 35 degrees C wires were within 2 degrees C of those claimed by the manufacturer, but the 40 degrees C wires were found to be nearer to 36 degrees C than 40 degrees C. Clinical use of CuNiTi wires resulted in few differences when compared with as-received wires analyzed by DSC. Two temperature varieties of CuNiTi are reasonably within the parameters of those identified by the manufacturer.Keywords
This publication has 23 references indexed in Scilit:
- How does temperature influence the properties of rectangular nickel-titanium wires?European Journal of Orthodontics, 2005
- Does the transition temperature of Cu–NiTi archwires affect the amount of tooth movement during alignment?Orthodontics & Craniofacial Research, 2004
- Micro-X-ray diffraction observation of nickel–titanium orthodontic wires in simulated oral environmentBiomaterials, 2004
- The load/deflection characteristics of thermally activated orthodontic archwiresEuropean Journal of Orthodontics, 2003
- Temperature- and deflection- dependences of orthodontic force with Ni-Ti wires.Dental Materials Journal, 2003
- Load-deflection characteristics of superelastic nickel-titanium orthodontic wiresAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2002
- Mechanical behavior at different temperatures and stresses for superelastic nickel–titanium orthodontic wires having different transformation temperaturesDental Materials, 2002
- The effect of short-term temperature changes on superelastic nickel-titanium archwires activated in orthodontic bendingAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2001
- Effect of copper addition on the superelastic behavior of Ni-Ti shape memory alloys for orthodontic applicationsJournal of Biomedical Materials Research, 1999
- Some factors determining the evaluation of forces in orthodonticsAmerican Journal of Orthodontics, 1957