Use of statistical parametric mapping (SPM) to enhance electrical impedance tomography (EIT) image sets
Authors:
- Y ZhangYZY Zhang
- T TidswellTTT Tidswell
- R H BayfordRBR H Bayford
- D S HolderDHD S Holder
- 26 June 2007
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 28 (7) , S141-S151
Abstract
Use of statistical parametric mapping (SPM), which is widely used in analysis of neuroimaging studies with fMRI and PET, has the potential to improve quality of EIT images for clinical use. Minimal modification to SPM is needed, but statistical analysis based on height, not extent thresholds, should be employed, due to the 20-80% variation of the point spread function, across EIT images. SPM was assessed in EIT images reconstructed with a linear time difference algorithm utilizing an anatomically realistic finite element model of the human head. Images of the average of data sets were compared with those produced using SPM over 10-40 individual image data sets without averaging. For a point disturbance, a sponge 15% of the diameter of an anatomically realistic saline-filled tank including a skull, with a contrast of 15%, and for visual evoked response data in 14 normal human volunteers, images produced with SPM were less noisy than the average images. For the human data, no consistent physiologically realistic changes were seen with either SPM or direct reconstruction; however, only a small data set was available, limiting the power of the SPM analysis. SPM may be used on EIT images and has the potential to extract improved images from clinical data series with a low signal-to-noise ratio.Keywords
This publication has 18 references indexed in Scilit:
- The effect of layers in imaging brain function using electrical impedance tomograghyPhysiological Measurement, 2004
- Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element methodNeuroImage, 2003
- Robust Smoothness Estimation in Statistical Parametric Maps Using Standardized Residuals from the General Linear ModelNeuroImage, 1999
- Electrical impedance tomography of complex conductivity distributions with noncircular boundaryIEEE Transactions on Biomedical Engineering, 1997
- Imaging of physiologically evoked responses by electrical impedance tomography with cortical electrodes in the anaesthetized rabbitPhysiological Measurement, 1996
- Three-dimensional electrical impedance tomographyNature, 1996
- Imaging cell volume changes and neuronal excitation in the hippocampal sliceNeuroscience, 1994
- An experimental study in electrical impedance tomography using backprojection reconstructionIEEE Transactions on Biomedical Engineering, 1991
- Applied potential tomography: a new noninvasive technique for assessing gastric functionClinical Physics and Physiological Measurement, 1987
- The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologistMedical & Biological Engineering & Computing, 1967