Accuracy of Transthoracic Echocardiography in Assessing Retro-aortic Rim prior to Device Closure of Atrial Septal Defects
- 16 September 2014
- journal article
- research article
- Published by Tech Science Press in Congenital Heart Disease
- Vol. 10 (4) , E146-E154
Abstract
Objective Deficient retro‐aortic rim has been identified as a risk factor for device erosion following trans‐catheter closure of atrial septal defects (ASDs). Transthoracic echocardiography (TTE) is the primary screening method for subjects for possible device closure of ASD, but its reliability in measuring retro‐aortic rim size has not been assessed previously. Design A single‐institution cross‐sectional analysis of children and adults referred for trans‐catheter device closure of single ostium secundum ASD from January 1, 2005 to April 1, 2012 with reviewable TTE and trans‐esophageal echocardiogram images was performed. Inter‐rater reliability of measurements was tested in a 24% sample. Accuracy of TTE measurement of retro‐aortic rim was assessed using a Bland–Altman plot with trans‐esophageal echocardiogram measurement as the gold standard. Test characteristics of TTE detection of deficient retro‐aortic rim were calculated. Risk factors for misclassification of deficient retro‐aortic rim were assessed using receiver operator characteristic curves. Risk factors for measurement error were assessed through multivariate linear regression. Results In total, 163 subjects of median age 5 years (range: 0.3–46 years) were included. Trans‐thoracic echocardiography had 90% sensitivity, 84% specificity, 90% positive predictive value, and 83% negative predictive value to detect deficient retro‐aortic rim. Bland–Altman plot demonstrated no fixed bias (P = .23), but errors in measurement increased on average as the aortic rim increased in size (P < .001). Prespecified patient level risk factors did not affect receiver operator characteristic curve area under the curve, nor were any patient‐level risk factors independently associated with increased measurement error on TTE. Conclusions TTE is a sensitive and specific screening test for deficient retro‐aortic rim across a range of patient ages and sizes.Keywords
Funding Information
- National Institutes of Health (HL007915)
- Entelligence (N/a)
This publication has 27 references indexed in Scilit:
- Real-time 3-dimensional echocardiography in assessing atrial and ventricular septal defects: An echocardiographic-surgical correlative studyAmerican Heart Journal, 2004
- Comparison of costs of intracardiac echocardiography and transesophageal echocardiography in monitoring percutaneous device closure of atrial septal defect in children and adultsThe American Journal of Cardiology, 2004
- Transcatheter Atrial Septal Defect Closure Assisted by Intracardiac Echocardiography: 3‐Year Follow‐UpJournal of Interventional Cardiology, 2004
- Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defectThe American Journal of Cardiology, 2004
- Two-dimensional echocardiographic and color doppler measurements of atrial septal defect, and comparison with the balloon-stretched diameterThe American Journal of Cardiology, 1993
- Biplane transesophageal echo-Doppler studies of atrial septal defects: Quantitative evaluation and monitoring for transcatheter closureAmerican Heart Journal, 1993
- Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusionAmerican Heart Journal, 1992
- Relationship of echocardiographic, shunt flow, and angiographic size to the stretched diameter of the atrial septal defectAmerican Heart Journal, 1991
- Diagnosis and quantitative evaluation of secundum-type atrial septal defect by transesophageal Doppler echocardiographyThe American Journal of Cardiology, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986