In‐source fragmentation and correlation analysis as tools for metabolite identification exemplified with CE‐TOF untargeted metabolomics
- 9 March 2015
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 36 (18) , 2188-2195
Abstract
The role of non‐targeted metabolomics with its discovery power is constantly growing in many different fields of science. However, its biggest advantage of uncovering the unexpected is turning into one of its biggest bottlenecks, particularly in metabolite identification. Among different methods for metabolite identification or ID confirmation, tandem MS analysis plays a very important role. However, this method is limited to only certain types of MS analysers, making for example TOF‐MS inaccessible for this type of metabolite identification. To overcome this, in‐source fragmentation has been used to fragment molecules and obtain product ions. Since the molecule of interest is not isolated prior to its fragmentation, the acquired spectrum contains many different signals arising from the fragmentation of all compounds present in the sample. Therefore, to assign product ions to their precursors, a novel use of correlation analysis was tested with r ≥0.9 as an assignation of a product ion belonging to the precursor. This method and chosen cut‐off was tested on three different sample complexity levels: conducting the analysis on a single standard, mix of co‐eluting standards and on a plasma sample. Obtained results clearly proved the effectiveness of the proposed methodology for metabolite ID confirmation. Moreover, the proposed strategy can be successfully applied for semi‐quantification of co‐eluting molecules with the same monoisotopic mass but that differ in fragmentation pattern. The proposed methodology can greatly improve the robustness and throughput of identification in metabolomics studies by use of TOF‐MS, which is crucial to obtain meaningful and trustful results.Keywords
Funding Information
- Spanish Ministry of Science and Technology (MCIT CTQ2011-23562)
This publication has 19 references indexed in Scilit:
- Method development and validation for rat serum fingerprinting with CE–MS: application to ventilator-induced-lung-injury studyAnalytical and Bioanalytical Chemistry, 2013
- Liquid chromatography quadrupole time-of-flight mass spectrometry characterization of metabolites guided by the METLIN databaseNature Protocols, 2013
- MetaboAnalyst 2.0--a comprehensive server for metabolomic data analysisNucleic Acids Research, 2012
- Combined Electron Transfer Dissociation–Collision-Induced Dissociation Fragmentation in the Mass Spectrometric Distinction of Leucine, Isoleucine, and Hydroxyproline Residues in Peptide Natural ProductsJournal of Proteome Research, 2011
- Automated workflows for accurate mass-based putative metabolite identification in LC/MS-derived metabolomic datasetsBioinformatics, 2011
- Metastable atom‐activated dissociation mass spectrometry: leucine/isoleucine differentiation and ring cleavage of proline residuesJournal of Mass Spectrometry, 2009
- How to discriminate between leucine and isoleucine by low energy ESI-TRAP MSnJournal of the American Society for Mass Spectrometry, 2007
- In‐source fragmentation and analysis of polysaccharides by capillary electrophoresis/mass spectrometryRapid Communications in Mass Spectrometry, 2005
- The origin of correlations in metabolomics dataMetabolomics, 2005
- Thirteen Ways to Look at the Correlation CoefficientThe American Statistician, 1988