High-Temperature Polarization Analysis of Polyethylene and Polyethylene- Semicon Bilayers
- 29 July 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2632-2641
Abstract
Crosslinked polyethylene (XLPE) is a key material for power cables due to its superior performance as electrical insulation. It is co-extruded with a carbon black-filled semiconducting “semicon” polymer layer, which is significantly more conductive than XLPE. Understanding the electrical properties of the XLPE/semicon bilayer and the interface between the layers is critical due to their common use in high-voltage cables, and so XLPE/semicon bilayers were developed, examined, and compared to XLPE in isolation. These materials were examined using current-voltage and dielectric displacement-voltage (D(P)-E) loop measurements. Current-voltage measurements were meant to examine changes in leakage current while D(P)-E loops were used to examine changes in dielectric loss, in both cases due to the addition of the semicon interface. Both techniques were used to analyze the charge transport response and development of space charge polarization in the bulk polymer and across the bilayer interface as a function of polarity at 90 °C. An increase in the apparent conductivity of the XLPE was measured when layered with the semicon, attributed to the increase in charge injection at the XLPE/semicon interface. Additionally, increases in the conductivity were observed with the application of higher electric fields. The addition of the semicon layer resulted in an increase in both the dielectric constant and the dielectric loss, and greater increases in both as the field is increased. Thus, it led to an enhancement in space charge polarization. Based on the experimental measurements from high-voltage D(P)-E loop measurement, a nonlinear circuit model was developed to fit the data and provide a close match to experimental values for resistivity and capacitance. The high-field circuit model was based on forward and reverse biased resistor and diode pathways in parallel with each other and with the bulk damped capacitor, and it predicts space charge limited conduction with a semicon electrode and Poole-Frenkel conduction with a metal electrode, highlighting the importance of interfaces on XLPE insulation performance.Keywords
Funding Information
- Dow (262574)
This publication has 24 references indexed in Scilit:
- Exploring the dielectric polarization and ionic conduction mechanisms in sodium-containing silicate and borosilicate glassesJournal of Non-Crystalline Solids, 2023
- Suppressing the Loss of Polymer‐Based Dielectrics for High Power Energy StorageAdvanced Materials, 2022
- Transient behavior of electrical conductivity in low‐density polyethylene in the presence of acetophenoneJournal of Applied Polymer Science, 2021
- Thermally stimulated depolarization current spectra of cross‐linked polyethylene and the influence of cross‐linking byproductsJournal of Polymer Science, 2020
- Intrinsic polymer dielectrics for high energy density and low loss electric energy storageProgress in Polymer Science, 2020
- Modeling of hysteresis loop and its applications in ferroelectric materialsCeramics International, 2018
- Homogeneous/Inhomogeneous‐Structured Dielectrics and their Energy‐Storage PerformancesAdvanced Materials, 2017
- Carbon Black for Electrically Conductive Polymer Applications2013
- Space charge studies of crosslinked polyethylene midvoltage cable insulation by thermally stimulated depolarization current, infrared/Fourier transform infrared, and scanning electron microscopyJournal of Polymer Science Part B: Polymer Physics, 2004
- Thermally stimulated depolarization currents of crosslinked polyethylene relaxations in the fusion range of temperaturesJournal of Polymer Science Part B: Polymer Physics, 2003