The Prevalence of and Predisposing Factors for Late Atrial Arrhythmias after Transcatheter Closure of Secundum Atrial Septal Defects in Children
Open Access
- 28 May 2023
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (11) , 3717
Abstract
Background: A 24 h Holter study in children after transcatheter secundum ASD (ASD II) closure was conducted to detect the prevalence of defects and/or device-related late atrial arrhythmias (LAAs). ASD II closure with an Amplatzer septal occluder (ASO) is an established procedure. Little is known about LAAs after device implantation. Methods: The eligible participants were children who had undergone ASO implantation, with a follow-up of ≥5 years, as well as one pre- and at least one post-procedural Holter ECG. Results: In total, 161 patients (mean age: 6.2 ± 4.3 years), with a mean follow-up of 12.9 ± 3.1 years (range 5–19), were included. A median of four Holter ECGs per patient were available. LAAs occurred before intervention in four patients (2.5%), and it was peri-interventional in four patients (2.5%), sustained in three patients (1.9%), and developed in three patients (1.9%). In patients with pre- and peri-interventional LAAs, the Qp/Qs ratio was higher (6.4 ± 3.9 vs. non-AA: 2.0 ± 1.1 (p = 0.002)) and the IAS/ASO ratio was lower (1.18 ± 0.27 vs. non-AA: 1.7 ± 0.4 (p < 0.001)). The patients with LAAs differed from those without LAAs in their Qp/Qs (6.8 ± 3.5 vs. 2.0 ± 1.3; p < 0.0001) and IAS/ASO ratios (1.14 ± 0.19 vs. 1.73 ± 0.45; p < 0.001). The patients with LAAs had a Qp/Qs ratio ≥2.94:1, and those who developed LAAs had an IAS/ASO ratio <1.15. Conclusions: LAAs occurred in 1.9% of patients and were sustained in another 1.9% of patients but persisted in those with large shunt defects and large occluders in relation to the atrial septal length. The predisposing factors for LAAs after ASD closure were a high Qp/Qs ratio, pre-existing atrial arrhythmias, and a low IAS/ASO ratio.Keywords
This publication has 55 references indexed in Scilit:
- Long-Term Follow Up of Secundum Atrial Septal Defect Closure with the Amplatzer Septal OccluderCongenital Heart Disease, 2010
- First experience With the biostar‐device for various applications in pediatric patients With congenital heart diseaseCatheterization and Cardiovascular Interventions, 2009
- The Influence of Morphological Changes in Amplatzer Device on the Atrial and Aortic Walls Following Transcatheter Closure of Atrial Septal DefectsJournal of Interventional Cardiology, 2009
- Short-term electrogeometric atrial remodelling after percutaneous atrial septal defect closureJournal of Cardiovascular Medicine, 2008
- Device closure of large atrial septal defects requiring devices ≥20 mm in small children weighing <20 kgCatheterization and Cardiovascular Interventions, 2008
- Transcatheter closure of atrial septal defect with Amplatzer® device in children aged less than 10 years old: Immediate and late follow-upCatheterization and Cardiovascular Interventions, 2008
- Intracardiac echocardiography to guide closure of atrial septal defects in children less than 15 kilogramsCatheterization and Cardiovascular Interventions, 2006
- Transcatheter closure of large atrial septal defects with the babic systemCatheterization and Cardiovascular Diagnosis, 1995
- Arrhythmias after repair of secundum atrial septal defect: The influence of surgical modificationAmerican Heart Journal, 1988
- Sinus node function and conduction system before and after surgery for secundum atrial septal defect: an electrophysiologic studyThe American Journal of Cardiology, 1984