Ideal-Observer Computation with Anthropomorphic Phantoms using Markov Chain Monte Carlo
Open Access
- 26 April 2022
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE International Symposium on Biomedical Imaging
- Vol. 2022, 1-5
Abstract
In medical imaging, it is widely recognized that image quality should be objectively evaluated based on performance in clinical tasks. To evaluate performance in signal-detection tasks, the ideal observer (IO) is optimal but also challenging to compute in clinically realistic settings. Markov Chain Monte Carlo (MCMC)-based strategies have demonstrated the ability to compute the IO using pre-computed projections of an anatomical database. To evaluate image quality in clinically realistic scenarios, the observer performance should be measured for a realistic patient distribution. This implies that the anatomical database should also be derived from a realistic population. In this manuscript, we propose to advance the MCMC-based approach to achieve these goals. We then use the proposed approach to study the effect of anatomical database size on IO computation for the task of detecting perfusion defects in simulated myocardial perfusion SPECT images. Our preliminary results provide evidence that the size of the anatomical database affects the computation of IO.Keywords
All Related Versions
Funding Information
- National Institute of Biomedical Imaging and Bioengineering
This publication has 17 references indexed in Scilit:
- Task-based measures of image quality and their relation to radiation dose and patient riskPhysics in Medicine & Biology, 2015
- Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observerJournal of Medical Imaging, 2015
- Design of a digital phantom population for myocardial perfusion SPECT imaging researchPhysics in Medicine & Biology, 2014
- An ideal-observer framework to investigate signal detectability in diffuse optical imagingBiomedical Optics Express, 2013
- Fisher information and surrogate figures of merit for the task-based assessment of image qualityJournal of the Optical Society of America A, 2010
- 4D XCAT phantom for multimodality imaging researchMedical Physics, 2010
- Adaptive SPECTIEEE Transactions on Medical Imaging, 2008
- Toward Realistic and Practical Ideal Observer (IO) Estimation for the Optimization of Medical Imaging SystemsIEEE Transactions on Medical Imaging, 2008
- Model observers for assessment of image quality.Proceedings of the National Academy of Sciences, 1993
- Estimating Trends in Historical HeightsHistorical Methods: A Journal of Quantitative and Interdisciplinary History, 1990