Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation
Authors:
- 18 April 2015
- journal article
- research article
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 104 (10) , 861-870
Abstract
The aim of this study was to evaluate the impact of contact force (CF) visualization on the incidence of low and high CF during left atrial (LA) mapping and pulmonary vein isolation (PVI). CF was assessed in 70 patients who underwent PVI. Three highly experienced operators performed all procedures. The operators were blinded to CF in group A (35 patients), and CF was displayed in group B (35 patients). In group B, optimal CF was defined as mean CF between 10 and 39g, and operators attempted to acquire points and ablate within this range. A total of 8401 mapping points were analyzed during LA mapping (group A: 4104, group B: 4297). Low CF g and high CF ≥40g were noted in a significantly larger number of points in group A (37.7 vs. 12.0 %, P < 0.001; 11.5 vs. 1.5 %, P < 0.001). At the mitral isthmus and ridge areas, CF was significantly lower (7.7 vs. 12.2g, P < 0.001; 5.3 vs. 11.7g, P < 0.001) in group A than in group B. PVI was successfully achieved in all patients. There were significant site-dependent CF differences between the two groups. Optimal CF was achieved in significantly more applications in group B (P < 0.001). There was no significant difference in atrial fibrillation (AF) recurrence rates after a minimum follow-up of 1 year between the two groups in this cohort (P = 0.24). No significant peri-procedural complications occurred in either group. CF visualization can assist in avoiding both low and high CF, which may have the potential to improve lesion formation and patient safety profile. In this study, CF-guided ablation did not affect AF recurrence.Keywords
This publication has 31 references indexed in Scilit:
- Impact of respiration gating on image integration guided atrial fibrillation ablationClinical Research in Cardiology, 2014
- Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: A prospective case control studyInternational Journal of Cardiology, 2013
- Left atrial isthmus line ablation using a remote robotic navigation system: feasibility, efficacy and long-term outcomeClinical Research in Cardiology, 2013
- The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA studyHeart Rhythm, 2012
- Contact force–controlled zero-fluoroscopy catheter ablation of right-sided and left atrial arrhythmia substratesHeart Rhythm, 2012
- Ipsilateral pulmonary vein isolation performed by a single continuous circular lesion: role of pulmonary vein mapping during ablationEP Europace, 2011
- Area Under the Real‐Time Contact Force Curve (Force–Time Integral) Predicts Radiofrequency Lesion Size in an In Vitro Contractile ModelJournal of Cardiovascular Electrophysiology, 2010
- Unexpected High Incidence of Esophageal Injury Following Pulmonary Vein Isolation Using Robotic NavigationJournal of Cardiovascular Electrophysiology, 2010
- The diagnostic yield from implantable loop recorders in children and young adultsClinical Research in Cardiology, 2007
- Recovered Pulmonary Vein Conduction as a Dominant Factor for Recurrent Atrial Tachyarrhythmias After Complete Circular Isolation of the Pulmonary VeinsCirculation, 2005