Field programmable gate array-based fault-tolerant hysteresis current control for AC machine drives
- 8 March 2012
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 6 (3) , 181-189
Abstract
This study presents a field programmable gate array (FPGA) implementation of a simple fault-tolerant control that ensures continuous operation of hysteresis current controlled AC machine drives under faulty current sensor. The adopted control requires the use of three current sensors and is available for three-phase isolated neutral systems. The third current sensor allows the faulty current sensor detection and isolation based on analytical redundancy that provides residuals with well-defined thresholds. The control is reconfigured in case of faulty current measurement and operation continuity is performed using the remaining two healthy sensors. The main interest of using FPGAs to implement such controllers is the very important reduction of execution time delay in spite of algorithm complexity. As a result, a high sampling frequency can be used and the residual thresholds can be accurately defined even for the experimental set-up. Numerous experimental results are given to illustrate the efficiency of FPGA-based solutions to achieve efficient and reliable fault-tolerant hysteresis current control of AC machine drives.Keywords
This publication has 19 references indexed in Scilit:
- Sensor fault detection and isolation in three-phase systems using a signal-based approachIET Control Theory & Applications, 2010
- Model for three-phase induction motors with stator core faultsIET Electric Power Applications, 2010
- Comparison between vibration and stator current analysis for the detection of bearing faults in asynchronous drivesIET Electric Power Applications, 2010
- DFIM vector control sensitivity with current sensor faultsCOMPEL - The international journal for computation and mathematics in electrical and electronic engineering, 2010
- Current Sensor Fault-Tolerant Control for WECS With DFIGIEEE Transactions on Industrial Electronics, 2009
- Doubly Fed Induction Generator Model-Based Sensor Fault Detection and Control Loop ReconfigurationIEEE Transactions on Industrial Electronics, 2009
- Detection of broken rotor bars in induction motor using starting-current analysis and effects of loadingIEE Proceedings - Electric Power Applications, 2006
- Current Sensor Fault Detection by Bilinear Observer for a Doubly Fed Induction Generator2006
- Application of Fully Decoupled Parity Equation in Fault Detection and Identification of DC MotorsIEEE Transactions on Industrial Electronics, 2006
- Fault Tolerant Three-Phase AC Motor Drive Topologies: A Comparison of Features, Cost, and LimitationsIEEE Transactions on Power Electronics, 2004