Distal access using hyperflexible atraumatic distal tip with optimized proximal stability of the Benchmark intracranial guide catheter for the treatment of cerebral vascular diseases: a technical note
Authors:
Open Access
- 12 June 2015
- journal article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 8 (7) , 718-721
Abstract
Background A stable guide catheter position within the intracranial vasculature is critical for safe, successful endovascular treatment. Objective To present ourinitial experience with the 0.071 inch inner diameter Benchmark guide catheter used in the treatment of intracranial cerebrovascular pathologies, demonstrating its safety and efficacy. Methods We retrospectively reviewed use of the Benchmark guide catheter from September through December 2014 in the management of various neuroendovascular intracranial pathologies. Clinical performance and complication rates were evaluated, with particular consideration of vessel tortuosity. A total of 62 Benchmarks were used, 47 in the anterior circulation, 10 in the posterior circulation, 4 in the external carotid, and 1 in the venous sinus. The five cases with access to the external carotid and venous sinus were excluded. Results The Benchmark was able to cross at least one 90° turn in 49 (86%) of the 57 patients. Reversal of the catheter was seen in 15% of 47 anterior circulation cases (4 at one 90° turn; 3 at two 90° turns). We report no complications of dissection or thromboembolic events. All guide catheter positions were safely achieved over a 0.035 Terumo stiff glidewire without need for an inner smaller lumen guide catheter for navigation. Conclusions Benchmark is a new guide catheter, with an ideal combination of both hyperflexible, atraumatic distal tip and optimized proximal shaft support to provide stable 6F primary access for a successful neurointerventional procedure. Benchmark can be easily, safely, and consistently positioned in a desired location within intracranial arteries providing a stable position for intervention and adequate angiography.Keywords
This publication has 12 references indexed in Scilit:
- Ultra-distal large-bore intracranial access using the hyperflexible Navien distal intracranial catheter for the treatment of cerebrovascular pathologies: a technical noteJournal of NeuroInterventional Surgery, 2013
- Initial experience with distal guide catheter placement in the treatment of cerebrovascular disease: clinical safety and efficacyJournal of NeuroInterventional Surgery, 2012
- Utilization of the Neuron 6 French 0.053 inch inner luminal diameter guide catheter for treatment of cerebral vascular pathology: continued experience with ultra distal access into the cerebral vasculatureJournal of NeuroInterventional Surgery, 2011
- Distal intracranial catheterization of patients with tortuous vascular anatomy using a new hybrid guide catheterSurgical Neurology, 2009
- Utility of the “buddy” wire in intracranial proceduresNeuroradiology, 2007
- Brain Aneurysms and Arteriovenous MalformationsStroke, 2007
- Efficacy of a direct puncture approach for anterior circulation aneurysms using a newly developed guiding catheter—especially for geriatric patientsSurgical Neurology, 2007
- Direct cervical arterial access for intracranial endovascular treatmentNeuroradiology, 2006
- Direct Carotid Puncture for the Endovascular Treatment of Anterior Circulation Aneurysms2006
- Techniques for Intracranial Stent Navigation in Patients with Tortuous Vessels2005