Influence of Alkyl Chain Length of Benzalkonium Chloride on Acute Corneal Epithelial Toxicity
Authors:
- Takeshi KumagamiTKTakeshi Kumagami
- Kenichiro ShimodaKSKenichiro Shimoda
- Mao KusanoMKMao Kusano
- Mugen TeshimaMTMugen Teshima
- Hitoshi SasakiHSHitoshi Sasaki
- Takashi KitaokaTKTakashi Kitaoka
- 1 November 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 29 (11) , 1296-1301
Abstract
To evaluate acute corneal epithelial toxicity induced by benzalkonium chloride (BAC) homologs with different alkyl chain lengths using an in vivo electrophysiological method. BAC homologs with C12, C14, and C16 alkyl chain lengths were used at concentrations of 0.0025%, 0.005%, and 0.01%, respectively. Cytotoxicity of BAC homologs on the normal rabbit corneal epithelial cells was examined by using a WST-1 assay. Corneal transepithelial electrical resistance (TER) was measured in living Japanese white rabbits by 2 Ag/AgCl electrodes placed in the anterior aqueous chamber and on the cornea. TER changes were then evaluated after a 60-second exposure to these BAC homologs. Morphological changes in corneal epithelium after exposure to the BAC homologs were examined using scanning electron microscopy. The antimicrobial activity of BAC homologs against Escherichia coli was also assessed. All BAC homologs caused cytotoxicity and corneal barrier dysfunction in a concentration-dependent manner. However, the degree of corneal toxicity differed among the BAC homologs. Based on cytotoxicity and TER measurement, C14-BAC caused the greatest corneal impairment followed in order of severity by mixed BAC/C16-BAC and C12-BAC. Scanning electron microscopy images indicated an intact corneal epithelium after exposure to 0.005% C12-BAC, whereas 0.005% C14-BAC damaged the epithelium. There were no remarkable differences noted in the antimicrobial activity among the BAC homologs. Acute corneal epithelial toxicity induced by BAC homologs depends on the alkyl chain length. Thus, the use of C12-BAC instead of commercially available BAC is potentially safer for patients undergoing ophthalmological pharmacotherapy.Keywords
This publication has 25 references indexed in Scilit:
- Breakdown Evaluation of Corneal Epithelial Barrier Caused by Antiallergic Eyedrops Using an Electrophysiologic MethodJournal of Ocular Pharmacology and Therapeutics, 2008
- Electrophysiological Characterization of Tight Junctional Pathway of Rabbit Cornea Treated with Ophthalmic IngredientsBiological and Pharmaceutical Bulletin, 2007
- Ocular toxicity of some corneal penetration enhancers evaluated by electrophysiology measurements on isolated rabbit corneasToxicology in Vitro, 2003
- Ocular tolerance of preservatives and alternativesEuropean Journal of Pharmaceutics and Biopharmaceutics, 2002
- Cytotoxicity of potential ocular permeation enhancers evaluated on rabbit and human corneal epithelial cell linesToxicology Letters, 2001
- Evaluation of Cytotoxicity of Various Ophthalmic Drugs, Eye Drop Excipients and Cyclodextrins in an Immortalized Human Corneal Epithelial Cell LinePharmaceutical Research, 1998
- The effects of ophthalmic preservatives on corneal epithelium of the rabbit: A scanning electron microscopical studyToxicology and Applied Pharmacology, 1982
- EFFECTS OF OPHTHALMIC VEHICLES ON THE STABILITY OF THE PRECORNEAL FILMActa Ophthalmologica, 1977
- EFFECTS OF BENZALKONIUM CHLORIDE UPON THE CORNEAL EPITHELIUM STUDIED WITH SCANNING ELECTRON MICROSCOPYActa Ophthalmologica, 1975
- Cytotoxicity of Ophthalmic PreservativesAmerican Journal of Ophthalmology, 1974