Calibration of MAJIS (Moons and Jupiter Imaging Spectrometer). IV. Radiometric calibration (invited)
- 1 November 2024
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Abstract
The MAJIS (Moons and Jupiter Imaging Spectrometer) instrument is an imaging spectrometer on-board the JUICE (JUpiter ICy moons Explorer) spacecraft. MAJIS covers the spectral range from 0.5 to 5.54 μm with two channels [visible–near infrared (VISNIR) and IR]. A comprehensive campaign of on-ground MAJIS calibration was conducted in August and September 2021 in the IAS (Institut d’Astrophysique Spatiale, CNRS/Université Paris-Saclay) facilities. In this article, we present the results relevant for the radiometric calibration of MAJIS. Due to the specific characteristics of the MAJIS detectors (H1RG from Teledyne), an extensive detector characterization campaign was implemented for both the VISNIR and IR detectors before integration so as to validate readout procedures providing precision and accuracy. The characterization also provided critical information on linearity and operability as a function of the integration time and operating temperature. The radiometric calibration of the integrated MAJIS instrument focused on the determination of the instrument transfer function in terms of DN output per unit of radiance for each MAJIS data element as a function of its position in the field of view of MAJIS and its central wavelength. The radiometric calibration of the VISNIR channel required a specific procedure due to stray light at short wavelengths. Observations of an internal calibration source during calibration and after launch (April 14, 2023) showed that there were minor changes in both the VISNIR and IR channels. The instrument transfer functions to be used in flight have been updated on this basis.Keywords
Funding Information
- Centre National d’Etudes Spatiales (CONTRACT CNES - CNRS n{degree sign} 180 117)
- Agenzia Spaziale Italiana (2021-18-I.0, ASI-INAF 2023-6-HH.0)
This publication has 20 references indexed in Scilit:
- Calibration of MAJIS (Moons and Jupiter Imaging Spectrometer): V. Validation with mineral samples and reference materialsReview of Scientific Instruments, 2024
- Calibration of MAJIS (Moons And Jupiter Imaging Spectrometer). II. Spatial calibrationReview of Scientific Instruments, 2024
- Moons and Jupiter Imaging Spectrometer (MAJIS) on Jupiter Icy Moons Explorer (JUICE)Space Science Reviews, 2024
- Calibration of MAJIS (Moons And Jupiter Imaging Spectrometer). III. Spectral calibrationReview of Scientific Instruments, 2024
- MAJIS/JUICE VIS-NIR FM and SM detectors characterization2020
- Characterization of transient signal induced in IR detector array by Jupiter high-energy electrons and implications for JUICE/MAJIS operabilityPlanetary and Space Science, 2020
- Euclid flight H2RG IR detectors: per pixel conversion gain from on-ground characterization for the Euclid NISP instrument2018
- Detectors for theJames Webb Space TelescopeNear‐Infrared Spectrograph. I. Readout Mode, Noise Model, and Calibration ConsiderationsPublications of the Astronomical Society of the Pacific, 2007
- Correlated Noise and Gain in Unfilled and Epoxy‐Underfilled Hybridized HgCdTe DetectorsPublications of the Astronomical Society of the Pacific, 2006
- Energy gap versus alloy composition and temperature in Hg1−xCdxTeJournal of Applied Physics, 1982