Abstract
Self-compacting concrete (SCC) is a fresh concrete that is able to flow and fill up the formwork by itself without the need of a vibrator to compact it. One of the reasons that causes the damage of a building structure during an earthquake is the heavy weight of its structural members which are from the high density of the material used such concrete material. Lightweight aggregate is one of the solutions to reduce the weight of the structure. Therefore, the SCC using the artificial lightweight aggregate (ALWA) is one of the solutions to reduce the self-weight (dead load) of a structure. This research was conducted to investigate the impact of the use of ALWA in conventional concrete and SCC in terms of its compressive strength and modulus of elasticity. To study the impact of the use of ALWA in SCC, several variation of percentage of ALWA as a substitution to the natural coarse aggregate was examined. The proportions of ALWA as a replacement to the coarse aggregate were 0%, 15%, 50%, and 100%. The test specimens were the cylindrical concrete of 200 mm in height and 100 mm in diameter for both compressive strength and modulus of elasticity tests. The results of the compressive strength test indicated that the higher the percentage of ALWA used in SCC, the lower the compressive strength of the concrete. The addition of ALWA as a substitution to the natural coarse aggregate to conventional concrete and SCC was found optimum at 15% replacement with the compressive strength of conventional concrete and SCC of 21.13 and 28.33 MPa, respectively. Whereas, the modulus of elasticity of the conventional concrete and SCC were found to be 20,843.99 and 23,717.77 MPa, respectively.Keywords
This publication has 20 references indexed in Scilit:
- Stress-strain relationship of high-strength steel (HSS) reinforcing barsAIP Conference Proceedings, 2018
- Mix design of light-weight self-compacting concreteCase Studies in Construction Materials, 2016
- Moment Contribution Capacity of Tendon Prestressed Partial on Concrete Beam-column Joint Interior According to Provisions ACI 318-2008 Chapter 21.5.2.5(c) Due to Cyclic Lateral LoadsMATEC Web of Conferences, 2016
- Performance of Square Reinforced Concrete Columns Externally Confined by Steel Angle Collars Under Combined Axial and Lateral LoadProcedia Engineering, 2015
- State-of-the-Art Report on Partially-prestressed Concrete Earthquake-resistant Building Structures for Highly-seismic RegionProcedia Engineering, 2014
- Mixed Concrete Optimization using Fly Ash, Silica Fume and Iron Slag on the SCC's Compressive StrengthProcedia Engineering, 2013
- Ductile Structure Framework of Earthquake Resistant of Highrise Building on Exterior Beam-Column Joint with the Partial Prestressed Concrete Beam-Column Reinforced ConcreteProcedia Engineering, 2013
- Axial Load Behavior of Concrete Columns with Welded Wire Fabric as Transverse ReinforcementProcedia Engineering, 2011
- Investigation of Stress-Strain Models for Confinement of Concrete by Welded Wire FabricProcedia Engineering, 2011