Time-resolved voltage measurements of Z-pinch radiation sources with a vacuum voltmeter
Authors:
- 1 October 2008
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 79 (10) , 10E306
Abstract
A vacuum-voltmeter (VVM) was fielded on the Saturn pulsed power generator during a series of argon gas-puff Z-pinch shots. Time-resolved voltage and separately measured load current are used to determine several dynamic properties as the load implodes, namely, the inductance, , net energy coupled to the load, , and the load radius, . The VVM is a two-stage voltage divider, designed to operate at voltages up to . The VVM is presently being modified to operate at voltages up to for eventual use on the Z generator.
Keywords
This publication has 2 references indexed in Scilit:
- A comparison of planar, laser-induced fluorescence, and high-sensitivity interferometry techniques for gas-puff nozzle density measurementsReview of Scientific Instruments, 2008
- Two-megavolt divider for pulsed high voltages in vacuumReview of Scientific Instruments, 1980