Time-resolved voltage measurements of Z-pinch radiation sources with a vacuum voltmeter

Authors:

Abstract
A vacuum-voltmeter (VVM) was fielded on the Saturn pulsed power generator during a series of argon gas-puff Z-pinch shots. Time-resolved voltage and separately measured load current are used to determine several dynamic properties as the load implodes, namely, the inductance, L(t) , net energy coupled to the load, Ecoupled(t) , and the load radius, r(t) . The VVM is a two-stage voltage divider, designed to operate at voltages up to 2MV . The VVM is presently being modified to operate at voltages up to 6MV for eventual use on the Z generator.

This publication has 2 references indexed in Scilit: