Cardiovascular Implantable Electronic Device Infections in Left Ventricular Assist Device Recipients
- 2 September 2013
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 37 (2) , 225-230
Abstract
Background: Most patients with left ventricular assist devices (LVADs) have concomitant cardiovascular implantable electronic devices (CIEDs). However, clinical presentation and outcome of CIED infection in the setting of LVAD has not been previously described.Methods: We retrospectively reviewed 247 patients who underwent LVAD implantation at Mayo Clinic campuses in Minnesota, Arizona, and Florida, from January 2005 to December 2011. Demographic and clinical data of patients who met criteria for CIED infection were extracted.Results: Of 247 patients with LVADs, 215 (87%) had CIED at the time of LVAD implantation and six (2.8%) subsequently developed CIED infections. Three patients developed CIED lead‐related endocarditis and the other three had pocket infection. All three instances of CIED pocket infection were preceded by device generator exchange, whereas all three patients with CIED lead‐related endocarditis had prior LVAD‐related infections. Causative pathogens included Pseudomonas aeruginos (1), coagulase‐negative staphylococci (2), methicillin‐resistant Staphylococcus aureus (1), a gram‐positive bacillus (1), and culture negative (2). All patients underwent complete CIED removal along with antimicrobial therapy. The three patients with CIED lead‐related endocarditis and prior LVAD infections received chronic suppressive antibiotic therapy, and one patient had LVAD exchange. All but one remained alive at the last follow‐up with a median duration of 15 months (7–46 months) from the time of CIED infection.Conclusion: Patients who are receiving LVAD therapy and develop CIED infection should be managed with complete CIED removal. Chronic suppressive antibiotic therapy is warranted in cases that have concomitant LVAD infection.Keywords
This publication has 15 references indexed in Scilit:
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Working formulation for the standardization of definitions of infections in patients using ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2011
- Clinical Predictors of Cardiovascular Implantable Electronic Device‐Related Infective EndocarditisPacing and Clinical Electrophysiology, 2011
- Cardiovascular Implantable Electronic Device Infection in Patients withStaphylococcus aureusBacteremiaPacing and Clinical Electrophysiology, 2010
- Update on Cardiovascular Implantable Electronic Device Infections and Their ManagementCirculation, 2010
- CDC/NHSN surveillance definition of health care–associated infection and criteria for specific types of infections in the acute care settingAmerican Journal of Infection Control, 2008
- Infective Endocarditis Complicating Permanent Pacemaker and Implantable Cardioverter-Defibrillator InfectionMayo Clinic Proceedings, 2008
- Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator InfectionsJACC, 2007
- Electrical and mechanical support in advanced heart failure. Rationale and feasibility of a combined management strategy.2002