Thermodynamic stability of xenon-doped liquid argon detectors
- 20 October 2023
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review C
- Vol. 108 (4) , 045503
Abstract
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.
Keywords
Funding Information
- Lawrence Livermore National Laboratory (DE-AC52-07NA27344, 20-SI-003, LLNL-JRNL-839368)
- National Nuclear Security Administration (DE-NA0000979, DE-NA0003996)
- U.S. Department of Energy (DE-SC0010007)
This publication has 54 references indexed in Scilit:
- Effects of Nitrogen contamination in liquid ArgonJournal of Instrumentation, 2010
- Pulse shape analysis of scintillation signals from pure and xenon-doped liquid argon for radioactive background identificationJournal of Instrumentation, 2008
- The ATLAS Liquid Argon Electromagnetic Calorimeter: Construction, Commissioning and Selected Test Beam ResultsIEEE Transactions on Instrumentation and Measurement, 2005
- Measurement and correlation of the (pressure, density, temperature) relation of argon II. Saturated-liquid and saturated-vapour densities and vapour pressures along the entire coexistence curveThe Journal of Chemical Thermodynamics, 1994
- Effect of ionization density on the time dependence of luminescence from liquid argon and xenonPhysical Review B, 1983
- Evidence of the existence of exciton states in liquid argon and exciton-enhanced ionization from xenon dopingPhysical Review B, 1976
- Dielectric constants and Clausius‐Mossotti functions for simple liquid mixtures: Systems containing nitrogen, argon and light hydrocarbonsAIChE Journal, 1975
- Liquid density and excess properties of argon + krypton and krypton + xenon binary liquid mixtures, and liquid density of ethaneTransactions of the Faraday Society, 1971
- Sublimation Pressures of Solid Ar, Kr, and XePhysical Review B, 1970
- Temperature and Density Dependence of the Molar Polarizability of XenonPhysical Review Letters, 1968